>
Fa   |   Ar   |   En
   Inhalation of diesel exhaust does not exacerbate cardiac hypertrophy or heart failure in two mouse models of cardiac hypertrophy  
   
نویسنده liu y. ,chien w.-m. ,medvedev i.o. ,weldy c.s. ,luchtel d.l. ,rosenfeld m.e. ,chin m.t.
منبع particle and fibre toxicology - 2013 - دوره : 10 - شماره : 1
چکیده    Background: strong associations have been observed between exposure to fine ambient particulate matter (pm2.5) and adverse cardiovascular outcomes. in particular,exposure to traffic related pm2.5 has been associated with increases in left ventricular hypertrophy,a strong risk factor for cardiovascular mortality. as much of traffic related pm2.5 is derived from diesel exhaust (de),we investigated the effects of chronic de exposure on cardiac hypertrophy and heart failure in the adult mouse by exposing mice to de combined with either of two mouse models of cardiac hypertrophy: angiotensin ii infusion or pressure overload induced by transverse aortic banding.methods: wild type male c57bl/6 j mice were either infused with angiotensin ii (800 ng/kg/min) via osmotic minipump implanted subcutaneously for 1 month,or underwent transverse aortic banding (27 gauge needle 1 week for observing acute reactions,26 gauge needle 3 months or 6 months for observing chronic reactions). vehicle (saline) infusion or sham surgery was used as a control. shortly after surgery,mice were transferred to our exposure facility and randomly assigned to either diesel exhaust (300 or 400 μg/m3) or filtered air exposures. after reaching the end of designated time points,echocardiography was performed to measure heart structure and function. gravimetric analysis was used to measure the ventricular weight to body weight ratio. we also measured heart rate by telemetry using implanted ambulatory ecg monitors.results: both angiotensin ii and transverse aortic banding promoted cardiac hypertrophy compared to vehicle or sham controls. transverse aortic banding for six months also promoted heart failure in addition to cardiac hypertrophy. in all cases,de failed to exacerbate the development of hypertrophy or heart failure when compared to filtered air controls. prolonged de exposure also led to a decrease in average heart rate.conclusions: up to 6-months of de exposure had no effect on cardiac hypertrophy and heart function induced by angiotensin ii stimulation or pressure overload in adult c57bl/6 j mice. this study highlights the potential importance of particle constituents of ambient pm2.5 to elicit cardiotoxic effects. further investigations on particle constituents and cardiotoxicity are warranted. © 2013 liu et al.; licensee biomed central ltd.
کلیدواژه Air pollution; Cardiac hypertrophy; Diesel exhaust; Heart failure; PM2.5
آدرس division of cardiology,department of medicine,university of washington,seattle,wa, United States, division of cardiology,department of medicine,university of washington,seattle,wa, United States, division of cardiology,department of medicine,university of washington,seattle,wa, United States, division of cardiology,department of medicine,university of washington,seattle,wa, United States, department of environmental and occupational health sciences,university of washington,seattle,wa, United States, department of environmental and occupational health sciences,university of washington,seattle,wa, United States, division of cardiology,department of medicine,university of washington,seattle,wa,united states,center for cardiovascular biology,university of washington school of medicine,850 republican street,box 358050,seattle 98109,wa, United States
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved