   Sensitivity and Specificity of a Prototype Rapid Diagnostic Test for the Detection of Trypanosoma brucei gambiense Infection: A Multi-centric Prospective Study  
   
نویسنده bisser s. ,lumbala c. ,nguertoum e. ,kande v. ,flevaud l. ,vatunga g. ,boelaert m. ,büscher p. ,josenando t. ,bessell p.r. ,biéler s. ,ndung’u j.m.
منبع plos neglected tropical diseases - 2016 - دوره : 10 - شماره : 4
چکیده    Background: a major challenge in the control of human african trypanosomiasis (hat) is lack of reliable diagnostic tests that are rapid and easy to use in remote areas where the disease occurs. in trypanosoma brucei gambiense hat,the card agglutination test for trypanosomiasis (catt) has been the reference screening test since 1978,usually on whole blood,but also in a 1/8 dilution (catt 1/8) to enhance specificity. however,the catt is not available in a single format,requires a cold chain for storage,and uses equipment that requires electricity. a solution to these challenges has been provided by rapid diagnostic tests (rdt),which have recently become available. a prototype immunochromatographic test,the sd bioline hat,based on two native trypanosomal antigens (vsg litat 1.3 and vsg litat 1.5) has been developed. we carried out a non-inferiority study comparing this prototype to the catt 1/8 in field settings. methodology/principal findings: the prototype sd bioline hat,the catt whole blood and catt 1/8 were systematically applied on fresh blood samples obtained from 14,818 subjects,who were prospectively enrolled through active and passive screening in clinical studies in three endemic countries of central africa: angola,the democratic republic of the congo and the central african republic. one hundred and forty nine hat cases were confirmed by parasitology. the sensitivity and specificity of the prototype sd bioline hat was 89.26% (95% confidence interval (ci) = 83.27–93.28) and 94.58% (95% ci = 94.20–94.94) respectively. the sensitivity and specificity of the catt on whole blood were 93.96% (95% ci = 88.92–96.79) and 95.91% (95% ci = 95.58–96.22),and of the catt 1/8 were 89.26% (95% ci = 83.27–93.28) and 98.88% (95% ci = 98.70–99.04) respectively. conclusion/significance: after further optimization,the prototype sd bioline hat could become an alternative to current screening methods in primary healthcare settings in remote,resource-limited regions where hat typically occurs. © 2016 bisser et al.
آدرس inserm umr1094,institute of neuroepidemiology and tropical neurology,limoges, France, programme national de lutte contre la trypanosomiase humaine africaine (pnltha),kinshasa, Congo, institut centrafricain de la recherche agronomique (icra),bangui, Central African Republic, programme national de lutte contre la trypanosomiase humaine africaine (pnltha),kinshasa, Congo, médecins sans frontières (msf) operational centre barcelona-athens (ocba),barcelona, Spain, instituto de combate e controlo das tripanossomiases,luanda, Angola, institute of tropical medicine antwerp,antwerpen, Belgium, institute of tropical medicine antwerp,antwerpen, Belgium, instituto de combate e controlo das tripanossomiases,luanda, Angola, epi interventions ltd.,edinburgh, United Kingdom, foundation for innovative new diagnostics,campus biotech,geneva, Switzerland, foundation for innovative new diagnostics,campus biotech,geneva, Switzerland
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved