>
Fa   |   Ar   |   En
   Sensitivity and Specificity of a Urine Circulating Anodic Antigen Test for the Diagnosis of Schistosoma haematobium in Low Endemic Settings  
   
نویسنده knopp s. ,corstjens p.l.a.m. ,koukounari a. ,cercamondi c.i. ,ame s.m. ,ali s.m. ,de dood c.j. ,mohammed k.a. ,utzinger j. ,rollinson d. ,van dam g.j.
منبع plos neglected tropical diseases - 2015 - دوره : 9 - شماره : 5
چکیده    Elimination of schistosomiasis as a public health problem and interruption of transmission in selected areas are key goals of the world health organization for 2025. conventional parasitological methods are insensitive for the detection of light-intensity infections. techniques with high sensitivity and specificity are required for an accurate diagnosis in low-transmission settings and verification of elimination. we determined the accuracy of a urine-based up-converting phosphor-lateral flow circulating anodic antigen (ucp-lf caa) assay for schistosoma haematobium diagnosis in low-prevalence settings in zanzibar,tanzania.a total of 1,740 urine samples were collected in 2013 from children on pemba island,from schools where the s. haematobium prevalence was <2%,2–5%,and 5–10%,based on a single urine filtration. on the day of collection,all samples were tested for microhematuria with reagent strips and for the presence of s. haematobium eggs with microscopy. eight months later,1.5 ml of urine from each of 1,200 samples stored at -20°c were analyzed by ucp-lf caa assay,while urine filtration slides were subjected to quality control (qcuf). in the absence of a true ‘gold’ standard,the diagnostic performance was calculated using latent class analyses (lca).the ‘empirical’ s. haematobium prevalence revealed by ucp-lf caa,qcuf,and reagent strips was 14%,5%,and 4%,respectively. lca revealed a sensitivity of the ucp-lf caa,qcuf,and reagent strips of 97% (95% confidence interval (ci): 91–100%),86% (95% ci: 72–99%),and 67% (95% ci: 52–81%),respectively. test specificities were consistently above 90%.the ucp-lf caa assay shows high sensitivity for the diagnosis of s. haematobium in low-endemicity settings. empirically,it detects a considerably higher number of infections than microscopy. hence,the ucp-lf caa employed in combination with qcuf,is a promising tool for monitoring and surveillance of urogenital schistosomiasis in low-transmission settings targeted for elimination. © 2015 knopp et al.
آدرس wolfson wellcome biomedical laboratories,department of life sciences,natural history museum,london,united kingdom,department of epidemiology and public health,swiss tropical and public health institute,basel,switzerland,university of basel,basel, Switzerland, department of molecular cell biology,leiden university medical center,leiden, Netherlands, biostatistics department,institute of psychiatry,psychology and neuroscience,kings college london,london, United Kingdom, laboratory of human nutrition,institute of food,nutrition,and health,eidgenössische technische hochschule (eth) zurich,zurich, Switzerland, public health laboratory-ivo de carneri,chake chake,pemba, Tanzania, public health laboratory-ivo de carneri,chake chake,pemba, Tanzania, department of molecular cell biology,leiden university medical center,leiden, Netherlands, helminth control laboratory unguja,ministry of health,zanzibar town,unguja, Tanzania, department of epidemiology and public health,swiss tropical and public health institute,basel,switzerland,university of basel,basel, Switzerland, wolfson wellcome biomedical laboratories,department of life sciences,natural history museum,london, United Kingdom, department of parasitology,leiden university medical center,leiden, Netherlands
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved