dual-wavelength plasmonic perfect absorber suitable for refractive index sensing
|
|
|
|
|
نویسنده
|
madadi zahra ,abedi kambiz ,darvish ghafar ,khatir mehdi
|
منبع
|
plasmonics - 2020 - دوره : 15 - شماره : 3 - صفحه:703 -708
|
چکیده
|
In this paper, a plasmonic perfect absorber (ppa) based on metal-insulator-metal-insulator-metal (mimim) structure has been designed for refractive index sensing of glucose solutions (analyte) and then a new method has been proposed for fast, low-cost, and easy measurement of sensor’s sensitivity. simulation results show that the absorption spectrum of the proposed sensor has two resonance peaks that with an increase in analyte refractive index, both of them are red-shifted. in our proposed measurement technique, two conventional single-wavelength lasers (with wavelengths of 1050 nm and 1750 nm) are used for vertical plane wave light illumination on the structure. then, the absorbed powers at 1750 nm (a2) and 1050 nm (a1) wavelengths are calculated and variation of the absorption ratio (a2/a1) due to change of analyte refractive index would be introduced as the sensitivity of sensor (s = δ(a2/a1)/δn). obtained results show that the increase of analyte refractive index from n = 1.312 to n = 1.384 will result in an increase of sensor’s sensitivity from 9.3/riu to 33.475/riu.
|
کلیدواژه
|
plasmonic perfect absorber ,refractive index sensor ,absorption ratio ,a new definition of sensitivity
|
آدرس
|
islamic azad university, science and research branch, department of electrical and computer engineering, iran, shahid beheshti university, faculty of electrical engineering, iran, islamic azad university, science and research branch, department of electrical and computer engineering, iran, islamic azad university, science and research branch, department of electrical and computer engineering, iran
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|