Fa   |   Ar   |   En
   Stability indicating RP-HPLC method for simultaneous determination of piroxicam and ofloxacin in binary combination  
   
نویسنده john p. ,azeem w. ,ashfaq m. ,khan i.u. ,razzaq s.n.
منبع pakistan journal of pharmaceutical sciences - 2015 - دوره : 28 - شماره : 5 - صفحه:1713 -1721
چکیده    A simple and precise rp-hplc method was developed for simultaneous determination of piroxicam and ofloxacin in pharmaceutical formulations and human serum. optimum separations of piroxicam,ofloxacin and stressinduced degradation products were achieved by use of hypersil bds c8 column (250 x 4.6mm,5μm). the mobile phase was a mixture of acetonitrile: 0.012m k2hpo4: 0.008m sodium citrate (both buffers mixed and ph adjusted to 2.8) (50:25:25 v/v/v) delivered at flow rate of 1.5ml min-1 using dad at 254nm. response was linear function of concentration over the ranges of 70-130mg ml-1 for piroxicam and ofloxacin (r2≥0.999). the method efficiently separated the analytical peaks from degradation products with acceptable tailing and resolution. the developed method was successfully used for concurrent analysis of piroxicam and ofloxacin in pharmaceutical formulations,human serum and in vitro drug interaction studies.
کلیدواژه Degradation products; Drug-drug interaction; Ofloxacin; Piroxicam
آدرس department of chemistry,government college university, Pakistan, department of chemistry,government college university, Pakistan, department of chemistry,h. h. campus,university of gujrat, Pakistan, department of chemistry,government college university, Pakistan, department of chemistry,government college university, Pakistan
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved