   Mathematical modeling and simulation of the preheating zone of a tunnel kiln  
   
نویسنده mançuhan e. ,küçükada k. ,alpman e.
منبع journal of thermal science and technology - 2011 - دوره : 31 - شماره : 2 - صفحه:79 -86
چکیده    Simulation of drying bricks in the preheating zone of a tunnel kiln was done by developing a one dimensional model describing the gas flow,heat transfer between gas and bricks and evaporation of bound water. simulation results were compared to the previously measured plant data. ambient air was fed into the preheating zone using two different profiles and vent locations to achieve desired gas temperature for high quality bricks. temperature profiles obtained using both approaches agreed well with measurements. when no ambient air is fed,gas temperature was shown to reach 350°c at the preheating zone entrance which is not desired for the best quality product. bound water in the bricks,which should be evaporated completely,approaches zero while reaching the 70% of the dimensionless length of the preheating zone. ©2008 tibtd printed in turkey.
کلیدواژه Evaporation of bound water; Gas temperature profile; Preheating zone simulation; Tunnel kiln
آدرس marmara university,faculty of engineering,mechanical engineering department,göztepe,kadiköy, Turkey, marmara university,faculty of engineering,chemical engineering department,göztepe,kadiköy, Turkey, marmara university,faculty of engineering,mechanical engineering department,göztepe,kadiköy, Turkey
 
     
   