Fa   |   Ar   |   En
   Transatrial access for left atrial pressure (LAP) monitoring line placement in Arterial switch operation (ASO) in neonates  
   
نویسنده Akhtar Mohammad Irfan ,Hamid Mohammad ,Amanullah Muneer ,Ahsan Khalid
منبع journal of the pakistan medical association - 2013 - دوره : 63 - شماره : 11 - صفحه:1430 -1432
چکیده    Left atrial pressure monitoring is a useful and accurate method to guide left ventricle filling in the patients who undergo arterial switch operation for transposition of great arteries. we have used a different technique in three tga patients for la pressure monitoring line placement. after cleaning and draping,right internal jugular vein (rt ijv) located through 22g venous cannula, guide wire was put in followed by sliding the 22gx8cm vygon arterial catheter over the guide wire into the right atrium that was directed transatrially into la by the operating surgeon during atrial septum repair. the catheter was secured by silk on the neck and dressed with transparent dressing and was kept for a period of 48-72hrs. la pressure monitoring is helpful in anticipating lv dysfunction in aso.
کلیدواژه Left atrial pressure ,Internal jugular vein ,Arterial switch operation
آدرس Aga Khan University Hospital, Department of Anaesthesia, Pakistan, Aga Khan University Hospital, Department of Anaesthesia, Pakistan, Aga Khan University Hospital, Department of Surgery, Pakistan, Aga Khan University Hospital, Department of Anaesthesia, Pakistan
 
     
   