>
Fa   |   Ar   |   En
   Reliability and day-to-day variability of peak fat oxidation during treadmill ergometry  
   
نویسنده de souza silveira r. ,carlsohn a. ,langen g. ,mayer f. ,scharhag-rosenberger f.
منبع journal of the international society of sports nutrition - 2016 - دوره : 13 - شماره : 1
چکیده    Background: exercising at intensities where fat oxidation rates are high has been shown to induce metabolic benefits in recreational and health-oriented sportsmen. the exercise intensity (fatpeak) eliciting peak fat oxidation rates is therefore of particular interest when aiming to prescribe exercise for the purpose of fat oxidation and related metabolic effects. although running and walking are feasible and popular among the target population,no reliable protocols are available to assess fatpeak as well as its actual velocity (vpfo) during treadmill ergometry. our purpose was therefore,to assess the reliability and day-to-day variability of vpfo and fatpeak during treadmill ergometry running. methods: sixteen recreational athletes (f = 7,m = 9; 25 ± 3 y; 1.76 ± 0.09 m; 68.3 ± 13.7 kg; 23.1 ± 2.9 kg/m2) performed 2 different running protocols on 3 different days with standardized nutrition the day before testing. at day 1,peak oxygen uptake (vo2peak) and the velocities at the aerobic threshold (vlt) and respiratory exchange ratio (rer) of 1.00 (vrer) were assessed. at days 2 and 3,subjects ran an identical submaximal incremental test (fat-peak test) composed of a 10 min warm-up (70 % vlt) followed by 5 stages of 6 min with equal increments (stage 1 = vlt,stage 5 = vrer). breath-by-breath gas exchange data was measured continuously and used to determine fat oxidation rates. a third order polynomial function was used to identify vpfo and subsequently fatpeak. the reproducibility and variability of variables was verified with an intraclass correlation coefficient (icc),pearson's correlation coefficient,coefficient of variation (cv) and the mean differences (bias) ± 95 % limits of agreement (loa). results: icc,pearson's correlation and cv for vpfo and fatpeak were 0.98,0.97,5.0 %; and 0.90,0.81,7.0 %,respectively. bias ± 95 % loa was -0.3 ± 0.9 km/h for vpfo and -2 ± 8 % of vo2peak for fatpeak. conclusion: in summary,relative and absolute reliability indicators for vpfo and fatpeak were found to be excellent. the observed loa may now serve as a basis for future training prescriptions,although fat oxidation rates at prolonged exercise bouts at this intensity still need to be investigated. © 2016 de souza silveira et al.
کلیدواژه Peak fat oxidation; Reliability; Running; Treadmill ergometry; Variability
آدرس university outpatient clinic,center of sports medicine,potsdam university,potsdam,germany,swiss federal institute of sport magglingen,magglingen, Switzerland, university outpatient clinic,center of sports medicine,potsdam university,potsdam,germany,university of education schwaebisch gmuend,department of health sciences,schwaebisch gmuend, Germany, university outpatient clinic,center of sports medicine,potsdam university,potsdam, Germany, university outpatient clinic,center of sports medicine,potsdam university,potsdam, Germany, university outpatient clinic,center of sports medicine,potsdam university,potsdam,germany,heidelberg university hospital,department of medical oncology,national center for tumor diseases (nct),heidelberg, Germany
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved