Flow Injection Spectrophotometric Determination of Total Iron in Fresh Waters using 1,10-Phenanthroline Reagent
|
|
|
|
|
نویسنده
|
ATTIQ-UR-REHMAN ,WASEEM AMIR ,YAQOOB MOHAMMAD ,ABDUL NABI
|
منبع
|
journal of the chemical society of pakistan - 2008 - دوره : 30 - شماره : 6 - صفحه:836 -840
|
چکیده
|
A simple flow injection method is reported for the determination of total iron in fresh waters based on spectrophotometric detection of reddish orange iron (ii)–1,10-phenanthroline complex measured at wavelength 510 nm. the system permits high throughput of 120 samples per hour. a linear calibration (r2 = 0.9981) graph was obtained over the concentration range 0.2-1.0 mg l-1 with relative standard deviation (n = 4) 0.6-1.0 %. the limit of detection (3s blank) was 0.01 mg l-1. the proposed method has been applied successfully for the determination of iron in fresh water samples and the results obtained (0.04 ± 0.003-0.09 ± 0.01 mg l-1) were in reasonable agreement with the results obtained using a spectrophotometric method (0.05±0.008-0.1±0.005 mg l-1) as the reference method.
|
|
|
آدرس
|
University of Balochistan, Department of Chemistry, Pakistan, University of Balochistan, Department of Chemistry, Pakistan, University of Balochistan, Department of Chemistry, Pakistan, University of Balochistan, Department of Chemistry, Pakistan
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
ATTIQ-UR-REHMAN ,ABDUL NABI
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|