Evaluation of beam hardening and photon scatter by brass compensator for IMRT
|
|
|
|
|
نویسنده
|
hashimoto s. ,karasawa k. ,fujita y. ,miyashita h. ,chang w. ,kawachi t. ,katayose t. ,kobayashi n. ,kunieda e. ,saitoh h.
|
منبع
|
journal of radiation research - 2012 - دوره : 53 - شماره : 6 - صفحه:999 -1005
|
چکیده
|
When a brass compensator is set in a treatment beam,beam hardening may take place. this variation of the energy spectrum may affect the accuracy of dose calculation by a treatment planning system and the results of dose measurement of brass compensator intensity modulated radiation therapy (imrt). in addition,when x-rays pass the compensator,scattered photons are generated within the compensator. scattered photons may affect the monitor unit (mu) calculation. in this study,to evaluate the variation of dose distribution by the compensator,dose distribution was measured and energy spectrum was simulated using the monte carlo method. to investigate the influence of beam hardening for dose measurement using an ionization chamber,the beam quality correction factor was determined. moreover,to clarify the effect of scattered photons generated within the compensator for the mu calculation,the head scatter factor was measured and energy spectrum analyses were performed. as a result,when x-rays passed the brass compensator,beam hardening occurred and dose distribution was varied. the variation of dose distribution and energy spectrum was larger with decreasing field size. this means that energy spectrum should be reproduced correctly to obtain high accuracy of dose calculation for the compensator imrt. on the other hand,the influence of beam hardening on kq was insignificant. furthermore,scattered photons were generated within the compensator,and scattered photons affect the head scatter factor. these results show that scattered photons must be taken into account for mu calculation for brass compensator imrt. © 2012 the author 2012. published by oxford university press on behalf of the japan radiation research society and japanese society for therapeutic radiology and oncology.
|
کلیدواژه
|
beam hardening; Brass compensator IMRT; dose distribution; quality correction factor; scatter photon
|
آدرس
|
tokyo metropolitan cancer and infectious diseases center komagome hospital,honkomagome 3-18-22,bunkyo-ku,tokyo 113-8677,japan,graduate school of human health sciences,tokyo metropolitan university,higashiogu 7-2-10,arakawa-ku,tokyo 116-8551, Japan, tokyo metropolitan cancer and infectious diseases center komagome hospital,honkomagome 3-18-22,bunkyo-ku,tokyo 113-8677, Japan, tohoku university,seiryocho 2-1,aoba-ku,sendai 980-8575, Japan, graduate school of human health sciences,tokyo metropolitan university,higashiogu 7-2-10,arakawa-ku,tokyo 116-8551, Japan, graduate school of human health sciences,tokyo metropolitan university,higashiogu 7-2-10,arakawa-ku,tokyo 116-8551, Japan, chiba cancer center,nitona-chou 666-2,chuo-ku,chiba 260-8717, Japan, association for nuclear technology in medicine,toranomon 1-8-16,minato-ku,tokyo 105-0001, Japan, graduate school of human health sciences,tokyo metropolitan university,higashiogu 7-2-10,arakawa-ku,tokyo 116-8551, Japan, tokai university,shimokasuya 143,isehara 259-1193, Japan, graduate school of human health sciences,tokyo metropolitan university,higashiogu 7-2-10,arakawa-ku,tokyo 116-8551, Japan
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|