>
Fa   |   Ar   |   En
   Evaluation of triple channel correction acquisition method for radiochromic film dosimetry  
   
نویسنده hayashi n. ,watanabe y. ,malmin r. ,kato h.
منبع journal of radiation research - 2012 - دوره : 53 - شماره : 6 - صفحه:930 -935
چکیده    The purpose of this study was to evaluate the triple channel correction acquisition (tcca) method for radiochromic film dosimetry performed with a flatbed scanner. the study had two parts: a fundamental and a clinical examination. in the fundamental examination,we evaluated the accuracy of calibration curves for gafchromic ebt2 (ebt2). the films were calibrated using a field-by-field method with 13 dose steps. seven calibration curves obtained by tcca were compared with those produced by a single channel acquisition (sca) method. for the clinical examination,we compared relative dose distributions obtained by tcca and sca for four cases of intensity-modulated radiation therapy (imrt) and intensity-modulated arc therapy (imat). the fundamental examination showed that the consistency of the calibration curves was better for tcca than for sca,particularly for the dose range between 0.25 gy and 1.00 gy. the clinical examination showed that the dose differences between the measured and calculated doses in high-gradient regions were smaller with tcca than with sca. the average pass rates in gamma analysis for the tcca and sca methods were 97.2 ± 0.8 (n = 20) and 93.0 ± 1.2 (n = 20),respectively. in conclusion,tcca can acquire accurate average dose values when creating the calibration curve. the potential advantage of tcca for ebt2 film dosimetry was seen in high-gradient regions in clinically relevant imrt and imat cases. tcca is useful to verify dose distribution. © 2012 the author 2012. published by oxford university press on behalf of the japan radiation research society and japanese society for therapeutic radiology and oncology.
کلیدواژه dose verification; film dosimetry; intensity-modulated radiation therapy; radiochromic film; Triple channel correction
آدرس faculty of radiological technology,school of health sciences,fujita health university,1-98,dengakugakubo,kutsukake-cho,toyoake,470-1192, Japan, department of therapeutic radiology,university of minnesota,minneapolis,mn,55455, United States, ridgeview regional radiation oncology,waconia,mn,55387, United States, faculty of radiological technology,school of health sciences,fujita health university,1-98,dengakugakubo,kutsukake-cho,toyoake,470-1192, Japan
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved