Fa   |   Ar   |   En
   The usefulness of an independent patient-specific treatment planning verification method using a benchmark plan in high-dose-rate intracavitary brachytherapy for carcinoma of the uterine cervix  
   
نویسنده takahashi y. ,koizumi m. ,sumida i. ,isohashi f. ,ogata t. ,akino y. ,yoshioka y. ,maruoka s. ,inoue s. ,konishi k. ,ogawa k.
منبع journal of radiation research - 2012 - دوره : 53 - شماره : 6 - صفحه:936 -944
چکیده    To develop an easy independent patient-specific quality assurance (qa) method using a benchmark plan for high-dose-rate intracavitary brachytherapy for cervix cancer,we conducted benchmark treatment planning with various sizes and combinations of tandem-ovoid and tandem-cylinder applications with 'ideal' geometry outside the patient. two-dimensional-based treatment planning was conducted based on the manchester method. we predicted the total dwell time of individual treatment plans from the air kerma strength,total dwell time and prescription dose of the benchmark plan. in addition,we recorded the height (dh),width (dw) and thickness (dt) covered with 100 isodose line. these parameters were compared with 169 and 29 clinical cases for tandem-ovoid or tandem-cylinder cases,respectively. with regard to tandem-ovoid cases,differences in total dwell time,dh,dt and dw between benchmark and individual plans were on average -0.2 ± 3.8,-1.0 mm ± 2.6 mm,0.8 mm ± 1.3 mm and -0.1 mm ± 1.5 mm,respectively. with regard to tandem-cylinder cases,differences in total dwell time,dhfront (the distance from tandem tip to tandem ring),dt and dw between benchmark and individual plans were on average -1.5 ± 3.1,-1.5 mm ± 4.9 mm,0.1 mm ± 1.0 mm and 0.2 mm ± 0.8 mm,respectively. of two cases,more than 13 differences in total dwell time were observed between benchmark plans and the clinical cases,which turned out to be due to the use of the wrong source position setting. these results suggest that our method is easy and useful for independent verification of patient-specific treatment planning qa. © 2012 the author 2012. published by oxford university press on behalf of the japan radiation research society and japanese society for therapeutic radiology and oncology.
کلیدواژه benchmark plan; high-dose-rate intracavitary brachytherapy; independent verification; Manchester method; treatment planning; uterine cervix
آدرس department of radiation oncology,osaka university graduate school of medicine,2-2 yamada-oka,suita,osaka,japan,division of medical physics,oncology center,osaka university hospital,2-15 yamada-oka,suita,osaka, Japan, division of medical physics,oncology center,osaka university hospital,2-15 yamada-oka,suita,osaka, Japan, department of radiology,osaka university graduate school of dental medicine,1-8 yamada-oka,suita,osaka, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamada-oka,suita,osaka, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamada-oka,suita,osaka,japan,division of medical physics,oncology center,osaka university hospital,2-15 yamada-oka,suita,osaka, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamada-oka,suita,osaka, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamada-oka,suita,osaka, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamada-oka,suita,osaka, Japan, department of medical technology,osaka university hospital,2-15 yamada-oka,suita,osaka, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamada-oka,suita,osaka, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamada-oka,suita,osaka, Japan
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved