   Characterization of MOSFET dosimeter angular dependence in three rotational axes measured free-In-Air and in soft-Tissue equivalent material  
   
نویسنده koivisto j. ,kiljunen t. ,wolff j. ,kortesniemi m.
منبع journal of radiation research - 2013 - دوره : 54 - شماره : 5 - صفحه:943 -949
چکیده    When performing dose measurements on an x-ray device with multiple angles of irradiation,it is necessary to take the angular dependence of metal-oxide-semiconductor field-effect transistor (mosfet) dosimeters into account. the objective of this study was to investigate the angular sensitivity dependence of mosfet dosimeters in three rotational axes measured free-in-air and in soft-tissue equivalent material using dental photon energy. free-in-air dose measurements were performed with three mosfet dosimeters attached to a carbon fibre holder. soft tissue measurements were performed with three mosfet dosimeters placed in a polymethylmethacrylate (pmma) phantom. all measurements were made in the isocenter of a dental conebeam computed tomography (cbct) scanner using 5° angular increments in the three rotational axes: axial,normal-to-axial and tangent-to-axial. the measurements were referenced to a radcal 1015 dosimeter. the angular sensitivity free-in-air (1 sd) was 3.7 ± 0.5 mv/mgy for axial,3.8 ± 0.6 mv/mgy for normalto- axial and 3.6 ± 0.6 mv/mgy for tangent-to-axial rotation. the angular sensitivity in the pmma phantom was 3.1 ± 0.1 mv/mgy for axial,3.3 ± 0.2 mv/mgy for normal-to-axial and 3.4 ± 0.2 mv/mgy for tangentto- axial rotation. the angular sensitivity variations are considerably smaller in pmma due to the smoothing effect of the scattered radiation. the largest decreases from the isotropic response were observed free-in-air at 90° (distal tip) and 270° (wire base) in the normal-to-axial and tangent-to-axial rotations,respectively. mosfet dosimeters provide us with a versatile dosimetric method for dental radiology. however,due to the observed variation in angular sensitivity,mosfet dosimeters should always be calibrated in the actual clinical settings for the beam geometry and angular range of the cbct exposure. © the author 2013. published by oxford university press on behalf of the japan radiation research society and japanese society for therapeutic radiology and oncology.
کلیدواژه Angular dependence; Dosimetry; MOSFET dosimeter; X-ray radiation exposure
آدرس department of physics,university of helsinki,gustaf hällströmin katu 2a,fi-00560 helsinki, Finland, international comprehensive cancer center docrates,saukonpaadenranta 2,fi-00180 helsinki, Finland, oral and maxillofacial unit,department of ortholaryngology,university of tampere,po box 2000,fi-33521 tampere,finland,medical imaging center,department of radiology,tampere university hospital,tampere, Finland, hus helsinki medical imaging center,university of helsinki,haartmaninkatu 4 (pob 340),helsinki,fi-00029 hus, Finland
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved