   Strength estimation of a moving 125iodine source during implantation in brachytherapy: Application to linked sources  
   
نویسنده tanaka k. ,endo s. ,tateoka k. ,asanuma o. ,hori m. ,takagi m. ,bengua g. ,kamo k.-i. ,sato k. ,takeda h. ,hareyama m. ,sakata k.-i. ,takada j.
منبع journal of radiation research - 2014 - دوره : 55 - شماره : 6 - صفحه:1146 -1152
چکیده    This study sought to demonstrate the feasibility of estimating the source strength during implantation in brachytherapy. the requirement for measuring the strengths of the linked sources was investigated. the utilized sources were 125i with air kerma strengths of 8.38-8.63 u (μgy m2 h-1). measurements were performed with a plastic scintillator (80 mm × 50 mm × 20 mm in thickness). for a source-to-source distance of 10.5 mm and at source speeds of up to 200 mm s-1,a counting time of 10 ms and a detector-to-needle distance of 5 mm were found to be the appropriate measurement conditions. the combined standard uncertainty (csu) with the coverage factor of 1 (k = 1) was ∼15% when using a grid to decrease the interference by the neighboring sources. without the grid,the csu (k = 1) was ∼5%,and an 8% overestimation due to the neighboring sources was found to potentially cause additional uncertainty. in order to improve the accuracy in estimating source strength,it is recommended that the measurment conditions should be optimized by considering the tradeoff between the overestimation due to the neighboring sources and the intensity of the measured value,which influences the random error. © the author 2014. published by oxford university press on behalf of the japan radiation research society and japanese society for radiation oncology.
کلیدواژه 125I ,source strength; Brachytherapy; Linked source; Moving source
آدرس department of medicine,graduate school,sapporo medical university,south 1,west 16,chuo-ward,sapporo hokkaido,060-8543, Japan, quantum energy applications,graduate school of engineering,hiroshima university,1-4-1,kagamiyama,higashi-hiroshima,hiroshima,739-8527, Japan, department of medicine,graduate school,sapporo medical university,south 1,west 16,chuo-ward,sapporo hokkaido,060-8543, Japan, division of radiology and nuclear medicine,sapporo medical university hospital,south 1,west 17,chuo-ward,sapporo hokkaido,060-8556, Japan, department of medicine,graduate school,sapporo medical university,south 1,west 16,chuo-ward,sapporo hokkaido,060-8543, Japan, hyogo ion beam medical center,1-2-1,kouto,shingu,tatsuno,hyogo,679-5165, Japan, auckland city hospital,park road,grafton,auckland,1142, New Zealand, department of medicine,graduate school,sapporo medical university,south 1,west 16,chuo-ward,sapporo hokkaido,060-8543, Japan, division of radiology and nuclear medicine,sapporo medical university hospital,south 1,west 17,chuo-ward,sapporo hokkaido,060-8556, Japan, division of radiology and nuclear medicine,sapporo medical university hospital,south 1,west 17,chuo-ward,sapporo hokkaido,060-8556, Japan, teishin-kai radiation therapy institute,1-6,north 44,east 8,higashi-ward,sapporo,hokkaido,007-0844, Japan, department of medicine,graduate school,sapporo medical university,south 1,west 16,chuo-ward,sapporo hokkaido,060-8543, Japan, department of medicine,graduate school,sapporo medical university,south 1,west 16,chuo-ward,sapporo hokkaido,060-8543, Japan
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved