   A robust measurement point for dose verification in delivery quality assurance for a robotic radiosurgery system  
   
نویسنده kurosu k. ,sumida i. ,shiomi h. ,mizuno h. ,yamaguchi h. ,okubo h. ,tamari k. ,seo y. ,suzuki o. ,ota s. ,inoue s. ,ogawa k.
منبع journal of radiation research - 2017 - دوره : 58 - شماره : 3 - صفحه:378 -385
چکیده    In this cyberknife® dose verification study,we investigated the effectiveness of the novel potential error (pe) concept when applied to the determination of a robust measurement point for targeting errors. pe was calculated by dividing the differences between the maximum increases and decreases in dose distributions by the original distribution after obtaining the former by shifting the source-to-axis and off-axis distances of each beam by ±1.0 mm. thus,pe values and measurement point dose heterogeneity were analyzed in 48 patients who underwent cyberknife radiotherapy. sixteen patients who received isocentric dose delivery were set as the control group,whereas 32 who received non-isocentric dose delivery were divided into two groups of smaller pe (spe) and larger pe (lpe) by using their median pe value. the mean dose differences (± standard deviations) were 1.0 ± 0.9%,0.5 ± 1.4% and 4.1 ± 2.8% in the control,spe and lpe groups,respectively. we observed significant correlations of the dose difference with the pe value (r = 0.582,p < 0.001) and dose heterogeneity (r = 0.471,p < 0.001). we concluded that when determining a robust measurement point for cyberknife point dose verification,pe evaluation was more effective than the conventional dose heterogeneity-based method that introduced optimal measurement point dose heterogeneity of <10% across the detector. © the author 2016. published by oxford university press on behalf of the japan radiation research society and japanese society for radiation oncology.
کلیدواژه CyberKnife; delivery quality assurance; dose prediction; QA
آدرس department of radiation oncology,osaka university graduate school of medicine,2-2 yamadaoka,suita,osaka,565-0871,japan,department of radiology,osaka university hospital,2-15 yamadaoka,suita,osaka,565-0871, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamadaoka,suita,osaka,565-0871, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamadaoka,suita,osaka,565-0871, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamadaoka,suita,osaka,565-0871, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamadaoka,suita,osaka,565-0871, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamadaoka,suita,osaka,565-0871, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamadaoka,suita,osaka,565-0871, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamadaoka,suita,osaka,565-0871, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamadaoka,suita,osaka,565-0871, Japan, department of radiology,osaka university hospital,2-15 yamadaoka,suita,osaka,565-0871, Japan, department of radiology,osaka university hospital,2-15 yamadaoka,suita,osaka,565-0871, Japan, department of radiation oncology,osaka university graduate school of medicine,2-2 yamadaoka,suita,osaka,565-0871, Japan
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved