   Endobronchial brachytherapy with curative intent: the impact of reference points setting according to the bronchial diameter  
   
نویسنده nomoto y. ,ii n. ,murashima s. ,yamashita y. ,ochiai s. ,takada a. ,toyomasu y. ,kawamura t. ,sakuma h.
منبع journal of radiation research - 2017 - دوره : 58 - شماره : 6 - صفحه:849 -853
چکیده    Endobronchial brachytherapy (ebb) is an effective treatment for endobronchial tumors. however,bronchial toxicity caused by over-irradiation remains problematic. to decrease bronchial toxicity,we developed a sourcecentralizing applicator for ebb. the purpose of the present study was to assess the efficacy and safety of ebb with varying reference dose points according to the bronchial diameter,using a source-centralizing applicator. we reviewed 15 patients with endobronchial carcinoma who were treated with curative intent using a combination of external beam radiotherapy (ebrt) and high-dose-rate ebb between 2005 and 2014. during each ebb session,we used a source-centralizing applicator that maintained the source-delivering catheter in the center of the bronchial lumen. reference dose points were 5-7 mm from the source axis,depending on the bronchial diameter. the median radiation doses of ebrt and ebb were 40 gy in 20 fractions and 18 gy in 3 fractions,respectively. the median observation period was 36 months. the 3-year overall survival,progression-free survival and local control rates were 79%,77% and 100%,respectively. grade 2 radiation pneumonitis was observed in two cases. bronchial toxicities,such as hemoptysis or the symptoms of chronic bronchitis,were not observed. ebb with varying reference dose points according to bronchial diameter,using a source-centralizing applicator,is a promising procedure that may be effective for tumor elimination and reducing toxicity to the bronchial wall. © the author 2017.
کلیدواژه Endobronchial brachytherapy; Lung cancer; Reference point
آدرس department of radiation oncology,graduate school of medicine,mie university,2-174 edobashi,tsu,mie,514-8507,japan,department of radiation oncology,mie university hospital,2-174 edobashi,tsu,mie,514-8507, Japan, department of radiation oncology,mie university hospital,2-174 edobashi,tsu,mie,514-8507, Japan, department of radiology,matsusaka central hospital,102 kobou kawai-machi,matsusaka,mie,515-8566, Japan, department of radiology,matsusaka central hospital,102 kobou kawai-machi,matsusaka,mie,515-8566, Japan, department of radiology,matsusaka central hospital,102 kobou kawai-machi,matsusaka,mie,515-8566, Japan, department of radiation oncology,mie university hospital,2-174 edobashi,tsu,mie,514-8507, Japan, department of radiation oncology,mie university hospital,2-174 edobashi,tsu,mie,514-8507, Japan, department of radiation oncology,mie university hospital,2-174 edobashi,tsu,mie,514-8507, Japan, department of radiology,graduate school of medicine,mie university,2-174 edobashi,tsu,mie,514-8507, Japan
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved