>
Fa   |   Ar   |   En
   evaluation of different respiratory gating schemes for cardiac spect  
   
نویسنده zhang duo ,pretorius p. hendrik ,ghaly michael ,zhang qi ,king michael a. ,mok greta s. p.
منبع journal of nuclear cardiology - 2020 - دوره : 27 - شماره : 2 - صفحه:634 -647
چکیده    Respiratory gating reduces motion blurring in cardiac spect. here we aim to evaluate the performance of three respiratory gating strategies using a population of digital phantoms with known truth and clinical data. we analytically simulated 60 projections for 10 xcat phantoms with 99mtc-sestamibi distributions using three gating schemes: equal amplitude gating (ag), equal count gating (cg), and equal time gating (tg). clinical list-mode data for 10 patients who underwent 99mtc-sestamibi scans were also processed using the 3 gating schemes. reconstructed images in each gate were registered to a reference gate, averaged and reoriented to generate the polar plots. for simulations, image noise, relative difference (rd) of averaged count for each of the 17 segment, and relative defect size difference (rsd) were analyzed. for clinical data, image intensity profile and fwhm were measured across the left ventricle wall. for simulations, ag and cg methods showed significantly lower rd and rsd compared to tg, while noise variation was more non-uniform through different gates for ag. in the clinical study, ag and cg had smaller fwhm than tg. ag and cg methods show better performance for motion reduction and are recommended for clinical respiratory gating spect implementation.
کلیدواژه respiratory gating ,cardiac perfusion ,spect/ct ,simulation
آدرس university of macau, faculty of science and technology, biomedical imaging laboratory (big), department of electrical and computer engineering, china. university of massachusetts medical school, department of radiology, usa, university of massachusetts medical school, department of radiology, usa, johns hopkins university, russell h morgan department of radiology and radiological science, usa. radiopharmaceutical imaging and dosimetry (rapid), llc, usa, university of macau, faculty of science and technology, biomedical imaging laboratory (big), department of electrical and computer engineering, china, university of massachusetts medical school, department of radiology, usa, university of macau, faculty of science and technology, faculty of health sciences, biomedical imaging laboratory (big), department of electrical and computer engineering, china. university of massachusetts medical school, department of radiology, usa
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved