>
Fa   |   Ar   |   En
   role of cardiac 123 i- m ibg imaging in predicting arrhythmic events in stable chronic heart failure patients with an icd  
   
نویسنده vincentis giuseppe de ,frantellizzi viviana ,fedele francesco ,farcomeni alessio ,scarparo paola ,salvi nicolò ,fegatelli danilo alunni ,mancone massimo ,verschure derk o. ,verberne hein j.
منبع journal of nuclear cardiology - 2019 - دوره : 26 - شماره : 4 - صفحه:1188 -1196
چکیده    Despite therapeutic improvement, the prognosis of chronic heart failure (chf) remains unfavorable partly due to arrhythmia and sudden cardiac death (scd). this prospective study evaluated myocardial 123i-meta-iodobenzylguanidine (123i-mibg) scintigraphy as a predictor of arrhythmic events (ae) in chf patients. 170 chf patients referred for implantable cardioverter-defibrillator (icd) implantation for both primary and secondary prevention were enrolled. all patients underwent planar and spect imaging. early and late heart-to-mediastinum (h/m) ratio, 123i-mibg washout (wo), early and late summed spect scores were calculated the primary endpoint was an ae: sustained ventricular tachycardia, resuscitated cardiac arrest, appropriate icd therapy or scd. the secondary endpoint was appropriate icd therapy. during a median follow-up of 23.3 months, 69 patients experienced an ae. early summed score (ess) was the only independent predictor of ae [hr 1.023 (1.003-1.043)]. focussing on only patients with an icd for primary prevention, ess was the only independent predictor of ae [hr 1.028 (1.007-1.050)]. 123i-mibg-derived parameters failed to be independent predictors of appropriate icd therapy. however there was a “bell-shaped” relation between 123i-mibg scintigraphy-derived parameters and ae and appropriate icd therapy, i.e., those with intermediate 123i-mibg abnormalities tended to be at higher risk of events. although spect 123i-mibg scintigraphy was associated with ae in chf patients with icd implantation for primary and secondary prevention, no association was found between 123i-mibg scintigraphy-derived parameters and appropriate icd therapy.
کلیدواژه 123i-mibg scintigraphy ,icd ,chronic heart failure ,planar ,spect ,heart-to-mediastinum ratio ,washout
آدرس sapienza - university of rome, department of radiological sciences, italy, sapienza - university of rome, department of radiological sciences, italy, sapienza - university of rome, department of cardiovascular, italy, sapienza - university of rome, department of public health and infectious diseases, italy, sapienza - university of rome, department of cardiovascular, italy, sapienza - university of rome, department of cardiovascular, italy, sapienza - university of rome, department of public health and infectious diseases, italy, sapienza - university of rome, department of cardiovascular, italy, zaans medical center, department of cardiology, the netherlands. university of amsterdam, academic medical center, department of radiology and nuclear medicine, the netherlands, university of amsterdam, academic medical center, department of radiology and nuclear medicine, the netherlands
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved