assessment of attenuation correction for myocardial pet imaging using combined pet/mri
|
|
|
|
|
نویسنده
|
lassen martin lyngby ,rasul sazan ,beitzke dietrich ,stelzmüller marie-elisabeth ,cal-gonzalez jacobo ,hacker marcus ,beyer thomas
|
منبع
|
journal of nuclear cardiology - 2019 - دوره : 26 - شماره : 4 - صفحه:1107 -1118
|
چکیده
|
To evaluate the frequency of artifacts in mr-based attenuation correction (ac) maps and their impact on the quantitative accuracy of pet-based flow and metabolism measurements in a cohort of consecutive heart failure patients undergoing combined pet/mr imaging. myocardial viability studies were performed in 20 patients following a dual-tracer protocol involving the assessment of myocardial perfusion (13n-nh3: 813 ± 86 mbq) and metabolism (18f-fdg: 335 ± 38 mbq). all acquisitions were performed using a fully-integrated pet/mr system, with standard dixon-attenuation correction (dixon-ac) mapping for each pet scan. all ac maps were examined for spatial misalignment with the emission data, total lung volume, susceptibility artifacts, and tissue inversion (ti). misalignment and susceptibility artifacts were corrected using rigid co-registration and retrospective filling of the susceptibility-induced gaps, respectively. the effects of the ac artifacts were evaluated by relative difference measures and perceived changes in clinical interpretations. average respiratory misalignment of (7 ± 4) mm of the pet-emission data and the ac maps was observed in 18 (90%) patients. substantial changes in the lung volumes of the ac maps were observed in the test–retest analysis (ratio: 1.0 ± 0.2, range: 0.8-1.4). susceptibility artifacts were observed in 10 (50%) patients, while six (30%) patients had ti artifacts. average differences of 14 ± 10% were observed for pet images reconstructed with the artifactual ac maps. the combined artifact effects caused false-positive findings in three (15%) patients. standard dixon-ac maps must be examined carefully for artifacts and misalignment effects prior to ac correction of cardiac pet/mri studies in order to avoid misinterpretation of biased perfusion and metabolism readings from the pet data.
|
کلیدواژه
|
attenuation correction ,cardiac pet ,artifacts ,pet/mr
|
آدرس
|
medical university of vienna, center for medical physics and biomedical engineering, general hospital vienna, qimp group, austria, medical university of vienna, division of nuclear medicine, department of biomedical engineering and image-guided therapy, austria, medical university of vienna, division of cardiovascular and interventional radiology, department of biomedical engineering and image-guided therapy, austria, medical university of vienna, department of cardiac surgery, austria, medical university of vienna, center for medical physics and biomedical engineering, general hospital vienna, qimp group, austria, medical university of vienna, division of nuclear medicine, department of biomedical engineering and image-guided therapy, austria, medical university of vienna, center for medical physics and biomedical engineering, general hospital vienna, qimp group, austria
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|