>
Fa   |   Ar   |   En
   Routine evaluation of left ventricular function using CZT-SPECT, with low injected activities and limited recording times  
   
نویسنده Claudin Marine ,Imbert Laetitia ,Djaballah Wassila ,Veran Nicolas ,Poussier Sylvain ,Roch Véronique ,Perrin Mathieu ,Verger Antoine ,Boutley Henri ,Karcher Gilles ,Marie Pierre-Yves
منبع journal of nuclear cardiology - 2018 - دوره : 25 - شماره : 1 - صفحه:249 -256
چکیده    Gamma-cameras, with cadmium-zinc-telluride (czt) detectors, allow to perform myocardial perfusion imaging (mpi) with limited injected activities and recorded times. this study aimed at determining whether the routine assessment of left ventricular (lv) function with such limited counts protocols compares well with reference values from cardiac mri. the study included patients who have undergone cardiac mri and an mpi routinely planned on a czt camera with a low-dose protocol (120 mbq of sestamibi for stress and 360 mbq at rest for 75 kg body weight), while targeting the recording of only 500 myocardial kcounts in order to limit the recording times (<10 minutes for stress, <4 minutes for rest). spect images were reconstructed with a method maintaining rather high spatial (8 mm) and temporal (16 frames/cycle) resolutions. seventy-six patients were included, and mean effective dose was 3.5 ± 1.7 msv for the total mpi protocol. correlations between czt-spect and mri were good to excellent for ejection fraction (r 2 = 0.77), end-diastolic (r 2 = 0.88) and end-systolic (r 2 = 0.93) volumes, and the analysis of segmental contractility correlated well between the two techniques (kappa score = 0.72 ± 0.02). lv function, assessed on a czt camera with low injected activities and limited recording times, correlates well with the reference assessment from cardiac mri.
کلیدواژه Myocardial perfusion imaging (MPI) ,gated-SPECT ,CZT camera ,Tc-99m Sestamibi ,left ventricular function
آدرس Department of Nuclear Medicine, CHU-Nancy, France, Department of Nuclear Medicine, CHU-Nancy, France. Nancyclotep Molecular Imaging Platform, France. UMR 7039 CRAN and Université de Lorraine, France, Department of Nuclear Medicine, CHU-Nancy, France. INSERM U947 and Université de Lorraine, France, Department of Nuclear Medicine, CHU-Nancy, France. Nancyclotep Molecular Imaging Platform, France, Nancyclotep Molecular Imaging Platform, France. INSERM U947 and Université de Lorraine, France, Department of Nuclear Medicine, CHU-Nancy, France. Nancyclotep Molecular Imaging Platform, France, Department of Nuclear Medicine, CHU-Nancy, France, Department of Nuclear Medicine, CHU-Nancy, France. Nancyclotep Molecular Imaging Platform, France. INSERM U947 and Université de Lorraine, France, Nancyclotep Molecular Imaging Platform, France, Department of Nuclear Medicine, CHU-Nancy, France. Nancyclotep Molecular Imaging Platform, France. INSERM U947 and Université de Lorraine, France, Department of Nuclear Medicine, CHU-Nancy, France. Nancyclotep Molecular Imaging Platform, France. INSERM U1116 and Université de Lorraine, France
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved