Creation and characterization of normal myocardial perfusion imaging databases using the IQ·SPECT system
|
|
|
|
|
نویسنده
|
Okuda Koichi ,Nakajima Kenichi ,Matsuo Shinro ,Kondo Chisato ,Sarai Masayoshi ,Horiguchi Yoriko ,Konishi Takahiro ,Onoguchi Masahisa ,Shimizu Takeshi ,Kinuya Seigo
|
منبع
|
journal of nuclear cardiology - 2018 - دوره : 25 - شماره : 4 - صفحه:1328 -1337
|
چکیده
|
Image acquisition by short-time single-photon emission-computed tomography (spect) has been made feasible by iq·spect. the aim of this study was to generate normal databases (ndbs) of thallium-201 (201tl) myocardial perfusion imaging for iq·spect, and characterize myocardial perfusion distribution. we retrospectively enrolled 159 patients with a low likelihood of cardiac diseases from four hospitals in japan. all patients underwent short-time 201tl myocardial perfusion iq·spect with or without attenuation and scatter correction (acsc) in either supine or prone position. the mean myocardial counts were calculated using 17-segment polar maps. three ndbs were derived from supine and prone images as well as supine images with acsc. differences between the supine and prone positions were observed in the uncorrected sex-segregated ndbs in the mid-inferolateral counts (p ≤ 0.016 for males and p ≤ 0.002 for females). differences between iq·spect and conventional spect were also observed in the mid-anterior, inferolateral, and apical lateral counts (p ≤ 0.009 for males and p ≤ 0.003 for females). apical low counts attributed to myocardial thinning were observed in the apical anterior and apex segments in the supine iq·spect ndb with acsc. there were significant differences between uncorrected supine and prone ndbs, between uncorrected supine ndb and supine ndb with acsc, and between uncorrected supine ndb and conventional spect ndb. understanding the pattern of normal distribution in iq-spect short-time acquisitions with and without acsc will be helpful for interpretation of imaging findings in patients with coronary artery disease (cad) or low likelihood of cad and the ndbs will aid in quantitative analysis.
|
کلیدواژه
|
IQ·SPECT ,Multifocal collimator ,Myocardial perfusion imaging ,Short-time SPECT acquisition
|
آدرس
|
Kanazawa Medical University, Department of Physics, Japan, Kanazawa University Hospital, Department of Nuclear Medicine, Japan, Kanazawa University Hospital, Department of Nuclear Medicine, Japan, Tokyo Women’s Medical University Hospital, Department of Diagnostic Imaging and Nuclear Medicine, Japan, Fujita Health University Hospital, Department of Cardiology, Japan, National Hospital Organization Sagamihara National Hospital, Department of Cardiology, Japan, Kanazawa University Hospital, Department of Radiology, Japan, Kanazawa University, Department of Quantum Medical Technology, Japan, Department of Molecular Imaging, Siemens Healthcare K.K., Japan, Kanazawa University Hospital, Department of Nuclear Medicine, Japan
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|