   Impact of respiratory motion correction on SPECT myocardial perfusion imaging using a mechanically moving phantom assembly with variable cardiac defects  
   
نویسنده Polycarpou Irene ,Chrysanthou-Baustert Isabelle ,Demetriadou Ourania ,Parpottas Yiannis ,Panagidis Christoforos ,Marsden Paul K. ,Livieratos Lefteris
منبع journal of nuclear cardiology - 2017 - دوره : 24 - شماره : 4 - صفحه:1216 -1225
چکیده    The aim of this study was to determine the impact of respiratory motion correction on spect mpi and on defect detection using a phantom assembly. spect/ct data were acquired using an anthropomorphic phantom with inflatable lungs and with an ecg beating and moving cardiac compartment. the heart motion followed the respiratory pattern in the cranio-caudal direction to simulate normal or deep breathing. small or large transmural defects were inserted into the myocardial wall of the left ventricle. spect/ct images were acquired for each of the four respiratory phases, from exhale to inhale. a respiratory motion correction was applied using an image-based method with transformation parameters derived from the spect data by a non-rigid registration algorithm. a report on defect detection from two physicians and a quantitative analysis on mpi data were performed before and after applying motion correction. respiratory motion correction eliminated artifacts present in the images, resulting in a uniform uptake and reduction of motion blurring, especially in the inferior and anterior regions of the lv myocardial walls. the physicians’ report after motion correction showed that images were corrected for motion. a combination of motion correction with attenuation correction reduces artifacts in spect mpi. ac-spect images with and without motion correction should be simultaneously inspected to report on small defects.
کلیدواژه SPECT/CT ,myocardial perfusion defects ,motion correction ,cranio-caudal cardiac motion
آدرس King’s College London, Division of Imaging Sciences and Biomedical Engineering, UK. European University Cyprus, Department of Health Sciences, Cyprus, Frederick Research Center, Cyprus, Limassol General Hospital, Department of Nuclear Medicine, Cyprus, Frederick Research Center, Cyprus. Frederick University, General Department (Physics-Mathematics), Cyprus, Nicosia General Hospital, Department of Nuclear Medicine, Cyprus, King’s College London, Division of Imaging Sciences and Biomedical Engineering, UK, King’s College London, Division of Imaging Sciences and Biomedical Engineering, UK. Guy’s and St Thomas’ Hospitals NHS Foundation Trust, UK
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved