>
Fa   |   Ar   |   En
   Comparison of the diagnostic accuracies of very low stress-dose with standard-dose myocardial perfusion imaging: Automated quantification of one-day, stress-first SPECT using a CZT camera  
   
نویسنده Sharir Tali ,Pinskiy Marina ,Pardes Abraham ,Rochman Arik ,Prokhorov Vitali ,Kovalski Gil ,Merzon Konstantine ,Bojko Andrzej ,Brodkin Boris
منبع journal of nuclear cardiology - 2016 - دوره : 23 - شماره : 1 - صفحه:11 -20
چکیده    Previous studies have demonstrated accurate diagnosis of reduced dose myocardial perfusion imaging (mpi) using cadmium-zinc-telluride (czt) technology. we compared the diagnostic performances of very low stress-dose (<2 msv) with standard-dose stress-first, quantitative mpi using a czt camera. patients without known coronary artery– disease who underwent a stress-first tc-99 m sestamibi czt-mpi and invasive coronary angiography (ica), and low-risk patients without ica were included. a stress-rest standard-dose (10/30 mci) mpi and a low-dose (5/15 mci) mpi were compared. normal limits for quantification were developed from 40 (20 males) low-risk patients, and total perfusion deficit (tpd) was derived. 208 patients who underwent mpi and ica, and 76 low-risk patients were included. of these, 128 had a standard-dose mpi and 156 had a low-dose mpi. stress-doses in low-dose and standard-dose groups were 5.9 ± 1.2 vs 10.2 ± 0.5 mci (1.7 ± 0.3 vs 3.0 ± 0.1 msv), respectively, p < 0.001, and stress-rest effective radiation was 6.9 ± 1.1 vs 11.7 ± 0.4 msv, respectively, p < 0.001. sensitivity, specificity, and accuracy values in the low-dose and standard-dose groups were 86.1%, 76.6%, and 81.4%; and 90.6%, 78.1%, and 84.4%, respectively, p = ns. using tpd prone, specificity values were 84.9% and 80.3%, respectively, p = ns. one-day stress-first mpi with 50% radiation reduction and a very low stress-dose (<2 msv) using czt technology and quantitative supine and prone analysis provided a high diagnostic value, similar to standard-dose mpi.
کلیدواژه Myocardial perfusion imaging ,low-dose ,stress-first ,CZT camera ,automatic quantification ,coronary artery disease
آدرس Assuta Medical Centers, Department of Nuclear Cardiology, Israel, Assuta Medical Centers, Department of Nuclear Cardiology, Israel, Assuta Medical Centers, Department of Nuclear Cardiology, Israel, Assuta Medical Centers, Department of Nuclear Cardiology, Israel, Assuta Medical Centers, Department of Nuclear Cardiology, Israel, General Electric Healthcare, Israel, Assuta Medical Centers, Department of Nuclear Cardiology, Israel, Assuta Medical Centers, Department of Nuclear Cardiology, Israel, Assuta Medical Centers, Department of Nuclear Cardiology, Israel. Barzilai Medical Center, Department of Cardiology, Israel. Ben-Gurion University of the Negev, Israel
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved