   Quantification of intramyocardial blood volume with 99mTc-RBC SPECT-CT imaging: A preclinical study  
   
نویسنده Hassan Mohy-ud-Din ,Nabil E. Boutagy ,John C. Stendahl ,Zhen W. Zhuang ,Albert J. Sinusas ,Chi Liu
منبع journal of nuclear cardiology - 2018 - دوره : 25 - شماره : 6 - صفحه:2096 -2111
چکیده    background:currently, there is no established non-invasive imaging approach to directly evaluate myocardial microcirculatory function in order to diagnose microvascular disease independent of co-existing epicardial disease. in this work, we developed a methodological framework for quantification of intramyocardial blood volume (imbv) as a novel index of microcirculatory function with spect/ct imaging of 99mtc-labeled red blood cells (rbcs). methods:dual-gated myocardial spect/ct equilibrium imaging of 99mtc-rbcs was performed on twelve canines under resting conditions. five correction schemes were studied: cardiac gating with no other corrections (cg), cg with attenuation correction (cg + ac), cg + ac with scatter correction (cg + ac + sc), dual cardiorespiratory gating with ac + sc (dg + ac + sc), and dg + ac + sc with partial volume correction (dg + ac + sc + pvc). quantification of imbv using each approach was evaluated in comparison to those obtained from all corrections. the in vivo spect estimates of imbv values were validated against those obtained from ex vivo microct imaging of the casted hearts. results:the estimated imbv with all corrections was 0.15 ± 0.03 for the end-diastolic phase and 0.11 ± 0.03 for the end-systolic phase. the cycle-dependent change in imbv (δimbv) with all corrections was 23.9 ± 8.6%. schemes that applied no correction or partial correction resulted in significant over-estimation of imbv and significant under-underestimation of δimbv. estimates of imbv and δimbv using all corrections were consistent with values reported in the literature using invasive techniques. in vivo spect estimates of imbv strongly correlated (r2 ≥ 0.70) with ex vivo measures for the various correction schemes, while the fully corrected scheme yielded the smallest bias. conclusion:snon-invasive quantification of imbv is feasible using 99mtc-rbcs spect/ct imaging, however, requires full compensation of physical degradation factors.
کلیدواژه Intramyocardial blood volume ,partial volume correction ,SPECT-CT imaging ,microCT ,coronary microcirculation ,cardio-respiratory motion correction
آدرس Yale University, Department of Radiology and Biomedical Imaging, USA. Shaukat Khanum Memorial Cancer Hospital and Research Center, Pakistan, Yale University School of Medicine, Section of Cardiovascular Medicine, Department of Medicine, USA, Yale University School of Medicine, Section of Cardiovascular Medicine, Department of Medicine, USA, Yale University School of Medicine, Section of Cardiovascular Medicine, Department of Medicine, USA, Yale University, Department of Radiology and Biomedical Imaging, USA. Yale University School of Medicine, Section of Cardiovascular Medicine, Department of Medicine, USA, Yale University, Department of Radiology and Biomedical Imaging, USA
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved