>
Fa   |   Ar   |   En
   ISway: A sensitive,valid and reliable measure of postural control  
   
نویسنده mancini m. ,salarian a. ,carlson-kuhta p. ,zampieri c. ,king l. ,chiari l. ,horak f.b.
منبع journal of neuroengineering and rehabilitation - 2012 - دوره : 9 - شماره : 1
چکیده    Background: clinicians need a practical,objective test of postural control that is sensitive to mild neurological disease,shows experimental and clinical validity,and has good test-retest reliability. we developed an instrumented test of postural sway (isway) using a body-worn accelerometer to offer an objective and practical measure of postural control. methods. we conducted two separate studies with two groups of subjects. study i: sensitivity and experimental concurrent validity. thirteen subjects with early,untreated parkinsons disease (pd) and 12 age-matched control subjects (ctr) were tested in the laboratory,to compare sway from force-plate cop and inertial sensors. study ii: test-retest reliability and clinical concurrent validity. a different set of 17 early-to-moderate,treated pd (tested on medication),and 17 age-matched ctr subjects were tested in the clinic to compare clinical balance tests with sway from inertial sensors. for reliability,the sensor was removed,subjects rested for 30 min,and the protocol was repeated. thirteen sway measures (7 time-domain,5 frequency-domain measures,and jerk) were computed from the 2d time series acceleration (acc) data to determine the best metrics for a clinical balance test. results: both center of pressure (cop) and acc measures differentiated sway between ctr and untreated pd. jerk and time-domain measures showed the best test-retest reliability (jerk icc was 0.86 in pd and 0.87 in ctr; time-domain measures icc ranged from 0.55 to 0.84 in pd and from 0.60 to 0.89 in ctr). jerk,all but one time-domain measure,and one frequency measure were significantly correlated with the clinical postural stability score (r ranged from 0.50 to 0.63,0.01 < p < 0.05). conclusions: based on these results,we recommend a subset of the most sensitive,reliable,and valid isway measures to characterize posture control in pd: 1) jerk,2) rms amplitude and mean velocity from the time-domain measures,and 3) centroidal frequency as the best frequency measure,as valid and reliable measures of balance control from isway. © 2012 mancini et al.; licensee biomed central ltd.
کلیدواژه Accelerometers; Inertial sensors; Parkinsons disease; Postural control
آدرس department of neurology,school of medicine,oregon health and science university,505 nw 185th avenue,beaverton,or 97006,united states,biomedical engineering unit,department of electronics,computer science and systems,alma mater studiorum-universita di bologna,viale risorgimento 2,40136,bologna, Italy, department of neurology,school of medicine,oregon health and science university,505 nw 185th avenue,beaverton,or 97006, United States, department of neurology,school of medicine,oregon health and science university,505 nw 185th avenue,beaverton,or 97006, United States, functional and applied biomechanics laboratory,rehabilitation medicine department,national institutes of health,bethesda,md,20892, United States, department of neurology,school of medicine,oregon health and science university,505 nw 185th avenue,beaverton,or 97006, United States, biomedical engineering unit,department of electronics,computer science and systems,alma mater studiorum-universita di bologna,viale risorgimento 2,40136,bologna, Italy, department of neurology,school of medicine,oregon health and science university,505 nw 185th avenue,beaverton,or 97006, United States
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved