>
Fa   |   Ar   |   En
   Elbow spasticity during passive stretch-reflex: Clinical evaluation using a wearable sensor system  
   
نویسنده mcgibbon c.a. ,sexton a. ,jones m. ,o'connell c.
منبع journal of neuroengineering and rehabilitation - 2013 - دوره : 10 - شماره : 1
چکیده    Background: spasticity is a prevalent chronic condition among persons with upper motor neuron syndrome that significantly impacts function and can be costly to treat. clinical assessment is most often performed with passive stretch-reflex tests and graded on a scale,such as the modified ashworth scale (mas). however,these scales are limited in sensitivity and are highly subjective. this paper shows that a simple wearable sensor system (angle sensor and 2-channel emg) worn during a stretch-reflex assessment can be used to more objectively quantify spasticity in a clinical setting. methods. a wearable sensor system consisting of a fibre-optic goniometer and 2-channel electromyography (emg) was used to capture data during administration of the passive stretch-reflex test for elbow flexor and extensor spasticity. a kinematic model of unrestricted passive joint motion was used to extract metrics from the kinematic and emg data to represent the intensity of the involuntary reflex. relationships between the biometric results and clinical measures (mas,isometric muscle strength and passive range of motion) were explored. results: preliminary results based on nine patients with varying degrees of flexor and extensor spasticity showed that kinematic and emg derived metrics were strongly correlated with one another,were correlated positively (and significantly) with clinical mas,and negatively correlated (though mostly non-significant) with isometric muscle strength. conclusions: we conclude that a wearable sensor system used in conjunction with a simple kinematic model can capture clinically relevant features of elbow spasticity during stretch-reflex testing in a clinical environment. © 2013 mcgibbon et al.; licensee biomed central ltd.
کلیدواژه Elbow muscle tone; Modified Ashworth scale; Spasticity; Upper motor neuron syndrome
آدرس institute of biomedical engineering,university of new brunswick,25 dineen dr.,fredericton,nb e3b 5a3,canada,faculty of kinesiology,university of new brunswick,fredericton,nb, Canada, institute of biomedical engineering,university of new brunswick,25 dineen dr.,fredericton,nb e3b 5a3, Canada, stan cassidy centre for rehabilitation,fredericton,nb, Canada, faculty of kinesiology,university of new brunswick,fredericton,nb,canada,stan cassidy centre for rehabilitation,fredericton,nb, Canada
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved