چکیده
|
Background and aim: real-ear-to-coupler difference (recd) is affected by the type of transducer and its coupling method. this study aimed to investigate the effect of receiver type used in receiver-in-canal (ric) hearing aids on recd and coupler response for flat insertion gain (corfig) obtained by the same coupling method. methods: in this study, the right ears of 30 normal-hearing adults (25 men and 5 women, with a mean age of 28.13±5.62 years) were studied. we used the ric hearing aids with two standard and power receivers. the foam of the er-3a insert earphone was used as a coupling system in both receivers. by using the audiogram direct test within phonak’s fitting software, 70 db hl intensity was produced at different frequencies, once in the realear and again in the ha-1 coupler. by assessing the difference between real-ear and ha-1 coupler measurements, the recd was first obtained. then, the corfig was obtained at different frequencies by subtracting the microphone location effect (mle) and recd from real-ear unaided gain (reug). results: the recd and corfig values obtained from the standard receiver at all frequencies were significantly different from those from the power receiver (p<0.05), where the use of the power receiver resulted in lower recd and higher corfig. with the increase in frequency, the recd increased. a small frequency changes of 50 hz had a significant effect on recd and corfig. conclusion: the type of receiver used in ric hearing aids has a significant effect on the recd and corfig values.
|
کلیدواژه
|
real-ear measurement; real-ear-to-coupler difference; insertion gain; hearing aid
|
آدرس
|
university of social welfare and rehabilitation science, department of audiology, iran, shahid beheshti university of medical sciences, school of rehabilitation, department of audiology, iran, shahid beheshti university of medical sciences, school of rehabilitation, department of audiology, iran, shahid beheshti university of medical sciences, proteomics research center, school of allied medical sciences, department of biostatistics, iran
|
پست الکترونیکی
|
akbarzad@gmail.com
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|