   Comparison of long and short axis quantification of left ventricular volume parameters by cardiovascular magnetic resonance,with ex-vivo validation  
   
نویسنده childs h. ,ma l. ,ma m. ,clarke j. ,cocker m. ,green j. ,strohm o. ,friedrich m.g.
منبع journal of cardiovascular magnetic resonance - 2011 - دوره : 13 - شماره : 1
چکیده    Background: the purpose of the study was to compare the accuracy and evaluation time of quantifying left ventricular (lv),left atrial (la) volume and lv mass using short axis (sax) and long axis (lax) methods when using cardiovascular magnetic resonance (cmr). materials and methods. we studied 12 explanted canine hearts and 46 patients referred for cmr (29 male,age 47 18 years) in a clinical 1.5 t cmr system,using standard cine sequences. in standard short axis stacks of various slice thickness values in dogs and 8 mm slice thickness (gap 2 mm) in patients,we measured lv volumes using reference slices in a perpendicular,long axis orientation using certified software. volumes and mass were also measured in six radial long axis (lax) views. lv parameters were also assessed for intra- and inter-observer variability. in 24 patients,we also analyzed reproducibility and evaluation time of two very experienced (> 10 years of cmr reading) readers for sax and lax. results: in the explanted dog hearts,there was excellent agreement between ex vivo data and lv mass and volume data as measured by all methods for both,lax (r 2 = 0.98) and sax (r 2 = 0.88 to 0.98). la volumes,however,were underestimated by 13% using the lax views. in patients,there was a good correlation between all three assessed methods (r 2 0.95 for all). in experienced clinical readers,left-ventricular volumes and ejection fraction as measured in lax views showed a better inter-observer reproducibility and a 27% shorter evaluation time. conclusion: when compared to an ex vivo standard,both,short axis and long axis techniques are highly accurate for the quantification of left ventricular volumes and mass. in clinical settings,however,the long axis approach may be more reproducible and more time-efficient. therefore,the rotational long axis approach is a viable alternative for the clinical assessment of cardiac volumes,function and mass. © 2011 childs et al; licensee biomed central ltd.
آدرس departments of cardiac sciences and radiology,libin cardiovascular institute of alberta,university of calgary,ab, Canada, departments of cardiac sciences and radiology,libin cardiovascular institute of alberta,university of calgary,ab, Canada, departments of cardiac sciences and radiology,libin cardiovascular institute of alberta,university of calgary,ab, Canada, dept. of nuclear medicine and radiology,dalhousie university,halifax,nc, Canada, departments of cardiac sciences and radiology,libin cardiovascular institute of alberta,university of calgary,ab, Canada, departments of cardiac sciences and radiology,libin cardiovascular institute of alberta,university of calgary,ab,canada,siemens healthcare,henkestr. 12791054,erlangen, Germany, departments of cardiac sciences and radiology,libin cardiovascular institute of alberta,university of calgary,ab, Canada, departments of cardiac sciences and radiology,libin cardiovascular institute of alberta,university of calgary,ab, Canada
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved