Potential clinical impact of cardiovascular magnetic resonance assessment of ejection fraction on eligibility for cardioverter defibrillator implantation
|
|
|
|
|
نویسنده
|
joshi s.b. ,connelly k.a. ,jimenez-juan l. ,hansen m. ,kirpalani a. ,dorian p. ,mangat i. ,al-hesayen a. ,crean a.m. ,wright g.a. ,yan a.t. ,leong-poi h.
|
منبع
|
journal of cardiovascular magnetic resonance - 2012 - دوره : 14 - شماره : 1
|
چکیده
|
Background: for the primary prevention of sudden cardiac death,guidelines provide left ventricular ejection fraction (ef) criteria for implantable cardioverter defibrillator (icd) placement without specifying the technique by which it should be measured. we sought to investigate the potential impact of performing cardiovascular magnetic resonance (cmr) for ef on icd eligibility. methods. the study population consisted of patients being considered for icd implantation who were referred for ef assessment by cmr. patients who underwent cmr within 30 days of echocardiography were included. echocardiographic ef was determined by simpsons biplane method and cmr ef was measured by simpsons summation of discs method. results: fifty-two patients (age 6215 years,81% male) had a mean ef of 38 14% by echocardiography and 35 14% by cmr. cmr had greater reproducibility than echocardiography for both intra-observer (icc,0.98 vs 0.94) and inter-observer comparisons (icc 0.99 vs 0.93). the limits of agreement comparing cmr and echocardiographic ef were - 16 to +10 percentage points. cmr resulted in 11 of 52 (21%) and 5 of 52 (10%) of patients being reclassified regarding icd eligibility at the ef thresholds of 35 and 30% respectively. among patients with an echocardiographic ef of between 25 and 40%,9 of 22 (41%) were reclassified by cmr at either the 35 or 30% threshold. echocardiography identified only 1 of the 6 patients with left ventricular thrombus noted incidentally on cmr. conclusions: cmr resulted in 21% of patients being reclassified regarding icd eligibility when strict ef criteria were used. in addition,cmr detected unexpected left ventricular thrombus in almost 10% of patients. our findings suggest that the use of cmr for ef assessment may have a substantial impact on management in patients being considered for icd implantation. © 2012joshi et al.; licensee biomed central ltd.
|
کلیدواژه
|
Cardiovascular Magnetic Resonance; Echocardiography; Ejection Fraction; Implantable cardioverter defibrillators
|
آدرس
|
division of cardiology,st michaels hospital,university of toronto,30 bond st,toronto,on m5b 1w8, Canada, division of cardiology,st michaels hospital,university of toronto,30 bond st,toronto,on m5b 1w8, Canada, department of medical imaging,university health network,university of toronto,toronto, Canada, division of cardiology,schulich heart program,sunnybrook health sciences centre,toronto, Canada, department of medical imaging,st michaels hospital,university of toronto,toronto, Canada, division of cardiology,st michaels hospital,university of toronto,30 bond st,toronto,on m5b 1w8, Canada, division of cardiology,st michaels hospital,university of toronto,30 bond st,toronto,on m5b 1w8, Canada, division of cardiology,st michaels hospital,university of toronto,30 bond st,toronto,on m5b 1w8, Canada, department of medical imaging,university health network,university of toronto,toronto,canada,division of cardiology,university health network,university of toronto,toronto, Canada, department of medical biophysics,university of toronto and schulich heart program,sunnybrook health sciences centre,toronto, Canada, division of cardiology,st michaels hospital,university of toronto,30 bond st,toronto,on m5b 1w8, Canada, division of cardiology,st michaels hospital,university of toronto,30 bond st,toronto,on m5b 1w8, Canada
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|