   Evaluation of left ventricular ejection fraction using through-time radial GRAPPA  
   
نویسنده aandal g. ,nadig v. ,yeh v. ,rajiah p. ,jenkins t. ,sattar a. ,griswold m. ,gulani v. ,gilkeson r.c. ,seiberlich n.
منبع journal of cardiovascular magnetic resonance - 2014 - دوره : 16 - شماره : 1
چکیده    Background: the determination of left ventricular ejection fraction using cardiovascular magnetic resonance (cmr) requires a steady cardiac rhythm for electrocardiogram (ecg) gating and multiple breathholds to minimize respiratory motion artifacts,which often leads to scan times of several minutes. the need for gating and breathholding can be eliminated by employing real-time cmr methods such as through-time radial grappa. the aim of this study is to compare left ventricular cardiac functional parameters obtained using current gold-standard breathhold ecg-gated functional scans with non-gated free-breathing real-time imaging using radial grappa,and to determine whether scan time or the occurrence of artifacts are reduced when using this real-time approach. methods: 63 patients were scanned on a 1.5t cmr scanner using both the standard cardiac functional examination with gating and breathholding and the real-time method. total scan durations were noted. through-time radial grappa was employed to reconstruct images from the highly accelerated real-time data. the blood volume in the left ventricle was assessed to determine the end systolic volume (esv),end diastolic volume (edv),and ejection fraction (ef) for both methods,and images were rated for the presence of artifacts and quality of specific image features by two cardiac readers. linear regression analysis,bland-altman plots and two-sided t-tests were performed to compare the quantitative parameters. a two-sample t-test was performed to compare the scan durations,and a two-sample test of proportion was used to analyze the presence of artifacts. for the reviewers' ratings the wilcoxon test for the equality of the scores' distributions was employed. results: the differences in ef,edv,and esv between the gold-standard and real-time methods were not statistically significant (p-values of 0.77,0.82,and 0.97,respectively). additionally,the scan time was significantly shorter for the real-time data collection (p<0.001) and fewer artifacts were reported in the real-time images (p<0.01). in the qualitative image analysis,reviewers marginally preferred the standard images although some features including cardiac motion were equivalently rated. conclusion: real-time functional cmr with through-time radial grappa performed without ecg-gating under free-breathing can be considered as an alternative to gold-standard breathhold cine imaging for the evaluation of ejection fraction in patients. © 2014 aandal et al.; licensee biomed central ltd.
کلیدواژه Cardiac function; Cardiovascular magnetic resonance; Left ventricular ejection fraction; Real-time imaging
آدرس radiology,case western reserve university,university hospitals case medical center,cleveland,oh,united states,haraldsplass deaconess hospital,bergen, Norway, cardiology,metrohealth medical center,case western university,cleveland,oh, United States, case western reserve university school of medicine,cleveland,oh, United States, radiology,case western reserve university,university hospitals case medical center,cleveland,oh, United States, division of cardiovascular medicine,university hospitals case medical center,case western reserve university,cleveland,oh, United States, epidemiology and biostatistics,case western reserve university,cleveland,oh, United States, radiology,case western reserve university,university hospitals case medical center,cleveland,oh,united states,biomedical engineering,case western reserve university,rm. 309 wickenden bldg. 2071 martin luther king jr. dr.,cleveland,oh 44106-7207, United States, radiology,case western reserve university,university hospitals case medical center,cleveland,oh,united states,biomedical engineering,case western reserve university,rm. 309 wickenden bldg. 2071 martin luther king jr. dr.,cleveland,oh 44106-7207, United States, radiology,case western reserve university,university hospitals case medical center,cleveland,oh, United States, biomedical engineering,case western reserve university,rm. 309 wickenden bldg. 2071 martin luther king jr. dr.,cleveland,oh 44106-7207, United States
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved