   Immediate and 12 months follow up of function and lead integrity after cranial MRI in 356 patients with conventional cardiac pacemakers  
   
نویسنده muehling o.m. ,wakili r. ,greif m. ,von ziegler f. ,morhard d. ,brueckmann h. ,becker a.
منبع journal of cardiovascular magnetic resonance - 2014 - دوره : 16 - شماره : 1
چکیده    Background: conventional cardiac pacemakers are still often regarded as a contraindication to magnetic resonance imaging (mri). we conducted this study to support the hypothesis that it is safe to scan patients with cardiac pacemakers in a 1.5 tesla mri,if close supervision and monitoring as well as adequate pre- and postscan programming is provided. methods. we followed up 356 patients (age 61.3 ± 9.1 yrs.,229 men) with single (n = 132) or dual chamber (n = 224) cardiac pacemakers and urgent indication for a cranial mri for 12 months. the scans were performed at 1.5t. during the scan patients were monitored with a 3-lead ecg and pulse oximetry. prior to the scan pacemakers were programmed according to our own protocol. results: all 356 scans were completed without complications. no arrhythmias were induced,programmed parameters remained unchanged. no pacemaker dysfunction was identified. follow-up examinations were performed immediately,2 weeks,2,6,and 12 months after the scan. there was no significant change of pacing capture threshold (ventricular 0.9 ± 0.4 v@0.4 ms,atrial 0.9 ± 0.3 v@0.4 ms) immediately (ventricular 1.0 ± 0.3 v@0.4 ms,atrial 0.9 ± 0.4 v@0.4 ms) or at 12 months follow-up examinations (ventricular 0.9 ± 0.2 v@0.4 ms,atrial 0.9 ± 0.3 v@0.4 ms). there was no significant change in sensing threshold (8.0 ± 4.0 mv vs. 8.1 ± 4.2 mv ventricular lead,2.0 ± 0.9 mv vs. 2.1 ± 1.0 mv atrial lead) or lead impedance (ventricular 584 ± 179 ω vs. 578 ± 188 ω,atrial 534 ± 176 ω vs. 532 ± 169 ω) after 12 months. conclusions: this supports the evidence that patients with conventional pacemakers can safely undergo cranial mri in a 1.5t system with suitable preparation,supervision and precautions. long term follow-up did not reveal significant changes in pacing capture nor sensing threshold. © 2014muehling et al.; licensee biomed central ltd.
کلیدواژه Magnetic resonance imaging; Pacemaker; Safety
آدرس cardiology clinic harlaching,university of munich,munich, Germany, department of medicine,university of munich,munich, Germany, department of medicine,university of munich,munich, Germany, department of medicine,university of munich,munich, Germany, department of neuroradiology,university of munich,munich, Germany, department of neuroradiology,university of munich,munich, Germany, department of medicine,university of munich,munich, Germany
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved