>
Fa   |   Ar   |   En
   Characterization and quantification of dynamic eccentric regurgitation of the left atrioventricular valve after atrioventricular septal defect correction with 4D Flow cardiovascular magnetic resonance and retrospective valve tracking  
   
نویسنده calkoen e.e. ,westenberg j.j.m. ,kroft l.j.m. ,blom n.a. ,hazekamp m.g. ,rijlaarsdam m.e. ,jongbloed m.r.m. ,de roos a. ,roest a.a.w.
منبع journal of cardiovascular magnetic resonance - 2015 - دوره : 17 - شماره : 1
چکیده    Background: to characterize and directly quantify regurgitant jets of left atrioventricular valve (lavv) in patients with corrected atrioventricular septal defect (avsd) by four-dimensional (4d)flow cardiovascular magnetic resonance (cmr),streamline visualization and retrospective valve tracking. methods: medical ethical committee approval and informed consent from all patients or their parents were obtained. in 32 corrected avsd patients (age 26 ± 12 years),echocardiography and whole-heart 4dflow cmr were performed. using streamline visualization on 2- and 4-chamber views,the angle between regurgitation and annulus was followed throughout systole. on through-plane velocity-encoded images reformatted perpendicular to the regurgitation jet the cross-sectional jet circularity index was assessed and regurgitant volume and fraction were calculated. correlation and agreement between different techniques was performed with pearson's r and spearman's rho correlation and bland-altman analysis. results: in 8 patients,multiple regurgitant jets over the lavv were identified. median variation in regurgitant jet angle within patients was 36°(iqr 18-64°) on the 2-chamber and 30°(iqr 20-40°) on the 4-chamber. regurgitant jets had a circularity index of 0.61 ± 0.16. quantification of the regurgitation volume was feasible with 4dflow cmr with excellent correlation between lavv effective forward flow and aortic flow (r = 0.97,p < 0.001) for internal validation and moderate correlation with planimetry derived regurgitant volume (r = 0.65,p < 0.001) and echocardiographic grading (rho = 0.51,p = 0.003). conclusions: 4dflow cmr with streamline visualization revealed multiple,dynamic and eccentric regurgitant jets with non-circular cross-sectional shape in patients after avsd correction. 4dflow with retrospective valve tracking allows direct and accurate quantification of the regurgitation of these complex jets. © 2015 calkoen et al.
کلیدواژه 4DFlow; Atrioventricular septal defect; Cardiovascular magnetic resonance; Mitral valve regurgitation
آدرس department of paediatrics,division of paediatric cardiology,leiden,netherlands,department of anatomy and embryology,leiden, Netherlands, department of radiology,leiden, Netherlands, department of radiology,leiden, Netherlands, department of paediatrics,division of paediatric cardiology,leiden, Netherlands, department of thoracic surgery,leiden, Netherlands, department of paediatrics,division of paediatric cardiology,leiden, Netherlands, department of anatomy and embryology,leiden,netherlands,department of pediatric cardiology,leiden university medical center,j6 albinusdreef 2,leidenza 2333, Netherlands, department of radiology,leiden, Netherlands, department of paediatrics,division of paediatric cardiology,leiden, Netherlands
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved