Positive contrast spiral imaging for visualization of commercial nitinol guidewires with reduced heating
|
|
|
|
|
نویسنده
|
campbell-washburn a.e. ,rogers t. ,basar b. ,sonmez m. ,kocaturk o. ,lederman r.j. ,hansen m.s. ,faranesh a.z.
|
منبع
|
journal of cardiovascular magnetic resonance - 2015 - دوره : 17 - شماره : 1
|
چکیده
|
Background: cmr-guidance has the potential to improve tissue visualization during cardiovascular catheterization procedures and to reduce ionizing radiation exposure,but a lack of commercially available cmr guidewires limits widespread adoption. standard metallic guidewires are considered to be unsafe in cmr due to risks of rf-induced heating. here,we propose the use of rf-efficient gradient echo (gre) spiral imaging for reduced guidewire heating (low flip angle,long readout),in combination with positive contrast for guidewire visualization. methods: a gre spiral sequence with 8 interleaves was used for imaging. positive contrast was achieved using through-slice dephasing such that the guidewire appeared bright and the background signal suppressed. positive contrast images were interleaved with anatomical images,and real-time image processing was used to produce a color overlay of the guidewire on the anatomy. temperature was measured with a fiber-optic probe attached to the guidewire in an acrylic gel phantom and in vivo. results: left heart catheterization was performed on swine using the real-time color overlay for procedural guidance with a frame rate of 6.25 frames/second. using our standard cartesian real-time imaging (flip angle 60°),temperature increases up to 50 °c (phantom) and 4 °c (in vivo) were observed. in comparison,spiral gre images (8 interleaves,flip angle 10°) generated negligible heating measuring 0.37 °c (phantom) and 0.06 °c (in vivo). conclusions: the ability to use commercial metallic guidewires safely during cmr-guided catheterization could potentially expedite clinical translation of these methods. © 2015 campbell-washburn et al.
|
کلیدواژه
|
Guidewire; Interventional CMR; Non-Cartesian; Positive contrast; Real-time; Spiral; White marker
|
آدرس
|
cardiovascular and pulmonary branch,division of intramural research,national heart,lung,and blood institute,national institutes of health,bethesda,md 20892, United States, cardiovascular and pulmonary branch,division of intramural research,national heart,lung,and blood institute,national institutes of health,bethesda,md 20892, United States, cardiovascular and pulmonary branch,division of intramural research,national heart,lung,and blood institute,national institutes of health,bethesda,md 20892,united states,institute of biomedical engineering,bogazici university,istanbul, Turkey, cardiovascular and pulmonary branch,division of intramural research,national heart,lung,and blood institute,national institutes of health,bethesda,md 20892, United States, cardiovascular and pulmonary branch,division of intramural research,national heart,lung,and blood institute,national institutes of health,bethesda,md 20892,united states,institute of biomedical engineering,bogazici university,istanbul, Turkey, cardiovascular and pulmonary branch,division of intramural research,national heart,lung,and blood institute,national institutes of health,bethesda,md 20892, United States, cardiovascular and pulmonary branch,division of intramural research,national heart,lung,and blood institute,national institutes of health,bethesda,md 20892, United States, cardiovascular and pulmonary branch,division of intramural research,national heart,lung,and blood institute,national institutes of health,bethesda,md 20892, United States
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|