>
Fa   |   Ar   |   En
   Assessing exercise cardiac reserve using real-time cardiovascular magnetic resonance  
   
نویسنده le t.-t. ,bryant j.a. ,ting a.e. ,ho p.y. ,su b. ,teo r.c.c. ,gan j.s.-j. ,chung y.-c. ,o’regan d.p. ,cook s.a. ,chin c.w.-l.
منبع journal of cardiovascular magnetic resonance - 2017 - دوره : 19 - شماره : 1 - صفحه:1 -10
چکیده    Background: exercise cardiovascular magnetic resonance (excmr) has great potential for clinical use but its development has been limited by a lack of compatible equipment and robust real-time imaging techniques. we developed an excmr protocol using an in-scanner cycle ergometer and assessed its performance in differentiating athletes from non-athletes. methods: free-breathing real-time cmr (1.5t aera,siemens) was performed in 11 athletes (5 males; median age 29 [iqr: 28-39] years) and 16 age- and sex-matched healthy volunteers (7 males; median age 26 [interquartile range (iqr): 25-33] years). all participants underwent an in-scanner exercise protocol on a cmr compatible cycle ergometer (lode bv,the netherlands),with an initial workload of 25w followed by 25w-increment every minute. in 20 individuals,exercise capacity was also evaluated by cardiopulmonary exercise test (cpet). scan-rescan reproducibility was assessed in 10 individuals,at least 7 days apart. results: the excmr protocol demonstrated excellent scan-rescan (cardiac index (ci): 0.2 ± 0.5l/min/m2) and inter-observer (ventricular volumes: 1.2 ± 5.3ml) reproducibility. ci derived from excmr and cpet had excellent correlation (r = 0.83,p < 0.001) and agreement (1.7 ± 1.8l/min/m2). despite similar values at rest (p = 0.87),athletes had increased exercise ci compared to healthy individuals (at peak exercise: 12.2 [iqr: 10.2-13.5] l/min/m2 versus 8.9 [iqr: 7.5-10.1] l/min/m2,respectively; p < 0.001). peak exercise ci,where image acquisition lasted 13-17 s,outperformed that at rest (c-statistics = 0.95 [95% confidence interval: 0.87-1.00] versus 0.48 [95% confidence interval: 0.23-0.72],respectively; p < 0.0001 for comparison) in differentiating athletes from healthy volunteers; and had similar performance as vo2max (c-statistics = 0.84 [95% confidence interval = 0.62-1.00]; p = 0.29 for comparison). conclusions: we have developed a novel in-scanner excmr protocol using real-time cmr that is highly reproducible. it may now be developed for clinical use for physiological studies of the heart and circulation. © 2017 the author(s).
کلیدواژه Cardiopulmonary exercise test; Cardiovascular magnetic resonance; Exercise physiology; Supine bike ergometer
آدرس national heart centre singapore,5 hospital drive,singapore,169609, Singapore, national heart centre singapore,5 hospital drive,singapore,169609, Singapore, national heart centre singapore,5 hospital drive,singapore,169609, Singapore, national heart centre singapore,5 hospital drive,singapore,169609, Singapore, national heart centre singapore,5 hospital drive,singapore,169609, Singapore, changi general hospital,singapore, Singapore, siemens healthineers,erlangen, Germany, siemens healthineers,erlangen, Germany, mrc london institute of medical sciences,london, United Kingdom, national heart centre singapore,5 hospital drive,singapore,169609,singapore,duke-nus medical school,singapore,singapore,national heart and lung institute,imperial college,london, United Kingdom, national heart centre singapore,5 hospital drive,singapore,169609,singapore,duke-nus medical school,singapore, Singapore
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved