   Validation of diffusion tensor MRI measurements of cardiac microstructure with structure tensor synchrotron radiation imaging  
   
نویسنده teh i. ,mcclymont d. ,zdora m.-c. ,whittington h.j. ,davidoiu v. ,lee j. ,lygate c.a. ,rau c. ,zanette i. ,schneider j.e.
منبع journal of cardiovascular magnetic resonance - 2017 - دوره : 19 - شماره : 1
چکیده    Background: diffusion tensor imaging (dti) is widely used to assess tissue microstructure non-invasively. cardiac dti enables inference of cell and sheetlet orientations,which are altered under pathological conditions. however,dti is affected by many factors,therefore robust validation is critical. existing histological validation is intrinsically flawed,since it requires further tissue processing leading to sample distortion,is routinely limited in field-of-view and requires reconstruction of three-dimensional volumes from two-dimensional images. in contrast,synchrotron radiation imaging (sri) data enables imaging of the heart in 3d without further preparation following dti. the objective of the study was to validate dti measurements based on structure tensor analysis of sri data. methods: one isolated,fixed rat heart was imaged ex vivo with dti and x-ray phase contrast sri,and reconstructed at 100 μm and 3.6 μm isotropic resolution respectively. structure tensors were determined from the sri data and registered to the dti data. results: excellent agreement in helix angles (ha) and transverse angles (ta) was observed between the dti and structure tensor synchrotron radiation imaging (stsri) data,where hadti-stsri = -1.4° ± 23.2° and tadti-stsri = -1.4° ± 35.0° (mean ± 1.96 standard deviation across all voxels in the left ventricle). stsri confirmed that the primary eigenvector of the diffusion tensor corresponds with the cardiomyocyte long-axis across the whole myocardium. conclusions: we have used stsri as a novel and high-resolution gold standard for the validation of dti,allowing like-with-like comparison of three-dimensional tissue structures in the same intact heart free of distortion. this represents a critical step forward in independently verifying the structural basis and informing the interpretation of cardiac dti data,thereby supporting the further development and adoption of dti in structure-based electro-mechanical modelling and routine clinical applications. © 2017 the author(s).
کلیدواژه Cardiovascular magnetic resonance; Diffusion tensor imaging; Structure tensor; Synchrotron radiation imaging; Tissue microstructure; Validation
آدرس division of cardiovascular medicine,radcliffe department of medicine,university of oxford,oxford,united kingdom,leeds institute of cardiovascular and metabolic medicine,university of leeds,leeds, United Kingdom, division of cardiovascular medicine,radcliffe department of medicine,university of oxford,oxford, United Kingdom, diamond light source,didcot,united kingdom,department of physics and astronomy,university college london,london, United Kingdom, division of cardiovascular medicine,radcliffe department of medicine,university of oxford,oxford, United Kingdom, division of imaging sciences and biomedical engineering,king's college london,london, United Kingdom, division of imaging sciences and biomedical engineering,king's college london,london, United Kingdom, division of cardiovascular medicine,radcliffe department of medicine,university of oxford,oxford, United Kingdom, diamond light source,didcot,united kingdom,university of manchester,manchester,united kingdom,feinberg school of medicine,northwestern university,chicago, United States, diamond light source,didcot, United Kingdom, division of cardiovascular medicine,radcliffe department of medicine,university of oxford,oxford,united kingdom,leeds institute of cardiovascular and metabolic medicine,university of leeds,leeds, United Kingdom
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved