چکیده    Background: recent studies have shown that quantification of myocardial perfusion (mp) at stress and myocardial perfusion reserve (mpr) offer additional diagnostic and prognostic information compared to qualitative and semi-quantitative assessment of myocardial perfusion distribution in patients with coronary artery disease (cad). technical advancements have enabled fully automatic quantification of mp using cardiovascular magnetic resonance (cmr) to be performed in-line in a clinical workflow. the aim of this study was to validate the use of the automated cmr perfusion mapping technique for quantification of mp using 13n-nh3 cardiac positron emission tomography (pet) as the reference method. methods: twenty-one patients with stable cad were included in the study. all patients underwent adenosine stress and rest perfusion imaging with 13n-nh3 pet and a dual sequence,single contrast bolus cmr on the same day. global and regional mp were quantified both at stress and rest using pet and cmr. results: there was good agreement between global mp quantified by pet and cmr both at stress (-0.1 ± 0.5 ml/min/g) and at rest (0 ± 0.2 ml/min/g) with a strong correlation (r = 0.92,p < 0.001; y = 0.94× + 0.14). furthermore,there was strong correlation between cmr and pet with regards to regional mp (r = 0.83,p < 0.001; y = 0.87× + 0.26) with a good agreement (-0.1 ± 0.6 ml/min/g). there was also a significant correlation between cmr and pet with regard to global and regional mpr (r = 0.69,p = 0.001 and r = 0.57,p < 0.001,respectively). conclusions: there is good agreement between mp quantified by 13n-nh3 pet and dual sequence,single contrast bolus cmr in patients with stable cad. thus,cmr is viable in clinical practice for quantification of mp. © 2017 the author(s).
کلیدواژه Cardiac magnetic resonance; Myocardial perfusion; Myocardial perfusion reserve; Positron emission tomography
آدرس department of clinical physiology,clinical sciences,lund university,lund university hospital,lund, Sweden, national heart,lung,and blood institute,national institutes of health,dhhs,10 center drive,bethesda,md 20892, United States, department of clinical physiology,clinical sciences,lund university,lund university hospital,lund, Sweden, department of clinical physiology,clinical sciences,lund university,lund university hospital,lund, Sweden, department of radiation physics,lund university hospital,lund, Sweden, department of radiation physics,lund university hospital,lund, Sweden, department of clinical physiology,clinical sciences,lund university,lund university hospital,lund, Sweden, national heart,lung,and blood institute,national institutes of health,dhhs,10 center drive,bethesda,md 20892, United States, department of clinical physiology,clinical sciences,lund university,lund university hospital,lund,sweden,laboratory of computing,medical informatics and biomedical-imaging technologies,school of medicine,aristotle university of thessaloniki,thessaloniki, Greece, national heart,lung,and blood institute,national institutes of health,dhhs,10 center drive,bethesda,md 20892, United States, department of clinical physiology,clinical sciences,lund university,lund university hospital,lund, Sweden
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved