Fa   |   Ar   |   En
   reliability of shoulder rotators isometric strength test using a novel pulley electromechanical dynamometer. influence of the assessment position  
   
نویسنده chamorro claudio ,fuente carlos de la ,jerez daniel ,campos christian ,chirosa luis javier
منبع asian journal of sports medicine - 2018 - دوره : 9 - شماره : 2 - صفحه:1 -9
چکیده    Background: the shoulder complex, because of its relatively extensive freedom of motion, offers a great variety of testing positions and articular planes for strength examination. despite this, reliability of results are not clearly addressed. a novel pulley electrome- chanical dynamometer (fed) (functional electronic dynamometer) could be an alternative in strength assessment, however, the relative and absolute reliability have not been reported in the literature. objectives: to report the results of shoulder internal (ir) and rotators (er) peak torque reliability in two assessment positions by fed in asymptomatic subjects. methods: fifty-two healthy college students were included and tested twice within a two week period. in a supine position, the subjects randomly performed four isometric strength tests (i.e. ir at 40°, ir at 90°, er at 40°, and er at 90° of shoulder abduction). results: the intra-class correlation coefficients (icc) for relative reliability at 90° were 0.96 (0.94 - 0.98) for ir and 0.94 (0.90 - 0.96) for er. icc at 40° were 0.89 (0.80 - 0.94) for ir and 0.97 (0.94 - 0.98) for er. absolute reliability expressed as standard error of mea- surement compared to the mean (sem%) and 95% confidence interval (ci) of minimal detectable change percentage (mdc%) at 90° were 8.8% (-20.8, 28.4%) and 11.4% (-28.0, 35.2%) for er. mdc% at 40° were 12.6% (-35.5, 34.8%) for ir and 18.1% (-28.1, 35, 2%) for er. conclusions: isometric strength testing protocol using fed showed an excellent reproducibility and can be safely used in clinical settings to monitor the strength changes in a group of individuals or in a single individual.
کلیدواژه muscle strength dynamometry ,reliability of results ,rotator cuff
آدرس pontificia universidad catolica de chile, facultad de medicina, chile. universidad de atacama, chile. clínica uc san carlos de apoquindo, servicio kinesiologia, chile, universidad andres bello, facultad cs. de la rehabilitacion, chile. pontificia universidad catolica de chile, facultad de medicina, chile. universidad de atacama, chile, universidad andres bello, facultad cs. de la rehabilitacion, chile, universidad andres bello, facultad cs. de la rehabilitacion, chile, universidad de granada, departamento de educacion fisica y deportiva, spain
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved