   A comparative study of functional outcome of treatment of intra articular fractures of distal radius fixed with percutaneous Kirschner’s wires vs T-plate  
   
نویسنده khan j.i. ,hussain f.n. ,mehmood t. ,adil o.
منبع pakistan journal of medical sciences - 2017 - دوره : 33 - شماره : 3 - صفحه:709 -713
چکیده    Background & objective: fractures of the distal radius are common with a variable prognosis in case of intra articular extension. the available options include plaster,external fixation,prefabricated splintage using ligamentotaxis,k-wire fixation,and open reduction internal fixation with t-plate without an as yet clear advantage of one over the others. if these fractures are allowed to collapse,radial shortening,angulation and articular incongruity may cause permanent deformity and loss of function. this limited small scale study was intended to compare the functional results of treatment of these fractures with a t plate and k-wires. methods: this was a prospective experimental study conducted at department of orthopedics of pgmi/ lahore general hospital,lahore. total 30 patients were included and randomized into two groups of 15 patients each. group-a patients were treated with krischner’s wires and group-b patients were treated with a t-plate with open reduction. informed consent was taken. post operative follow up was done for 12 weeks for the outcome parameters (green and o’brien score). results: mean age of patients in group-a and b was 36.13±9.81 and 44.73±7.86 years respectively. in group-a there were 10 male and 5 female patients and in group-b there were 8 male and seven female patients respectively. in group-a nine patients presented with fernandez type-ii and six patients presented with fernandez type-iii fracture. while in group-b 10 patients presented with fernandez type-ii and five patients presented with fernandez type-iii fracture. among group-a patient’s final outcome was excellent in 86.67% patients while in group-b only 53.33% patients had excellent outcome at three months follow up. conclusion: percutaneous kirschner’s wires appeared to be more effective as compared to t‑plate fixation in terms of functional outcome for treating intra-articular distal radius fractures. © 2017,professional medical publications. all rights reserved.
کلیدواژه Distal radius; Intra-articular fractures; Kirschner’s wires; T-plate
آدرس 916-49 thorncliffe park drive,east york,toronto,on,canada,post graduate medical institute,lahore general hospital (lgh),lahore, Pakistan, avicenna medical college,dha 9,lahore cantt, Pakistan, post graduate medical institute,lahore general hospital (lgh),lahore, Pakistan, post graduate medical institute,lahore general hospital (lgh),lahore, Pakistan
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved