>
Fa   |   Ar   |   En
   Validity and reproducibility of an incremental sit-to-stand exercise test for evaluating anaerobic threshold in young,healthy individuals  
   
نویسنده nakamura k. ,ohira m. ,yokokawa y. ,nagasawa y.
منبع journal of sports science and medicine - 2015 - دوره : 14 - شماره : 4 - صفحه:708 -715
چکیده    Sit-to-stand exercise (sts) is a common activity of daily living. the objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ats),during incremental sit-to-stand exercise (ists) with and without arm support compared with an incremental cycle-ergometer (ce) test; and 2) to examine the reproducibility of the at measured during the istss. twenty-six healthy individuals randomly performed the ists and ce test. oxygen uptakes at the at (at-vo2) and heart rate at the at (at-hr) were determined during the istss and ce test,and repeated-measures analyses of variance and tukey’s post-hoc test were used to evaluate the differences between these variables. pearson correlation coefficients were used to assess the strength of the relationship between at-vo2 and at-hr during the istss and ce test. data analysis yielded the following correlations: at-vo2 during the ists with arm support and the ce test,r = 0.77 (p < 0.05); at-vo2 during the ists without arm support and the ce test,r = 0.70 (p < 0.05); at-hr during the ists with arm support and the ce test,r = 0.80 (p < 0.05); and at-hr during the ists without arm support and the ce test,r = 0.66 (p < 0.05). the at-vo2 values during the ists with arm support (18.5 ± 1.9 ml·min-1·kg-1) and the ce test (18.4 ± 1.8 ml·min-1·kg-1) were significantly higher than those during the ists without arm support (16.6 ± 1.8 ml·min-1·kg-1; p < 0.05). the at-hr values during the ists with arm support (126 ± 10 bpm) and the ce test (126 ± 13 bpm) were significantly higher than those during the ists without arm support (119 ± 9 bpm; p < 0.05). the ists with arm support may provide a cardiopulmonary function load equivalent to the ce test; therefore,it is a potentially valid test for evaluating at-vo2 and at-hr in healthy,young adults. © journal of sports science and medicine.
کلیدواژه Anaerobic threshold; Correlations; Cycle ergometer; Reproducibility; Sit-to-stand; Validity
آدرس department of rehabilitation,matsumoto city hospital,matsumoto,nagano,japan,department of health scienc-es,graduate school of medicine,shinshu university, Japan, department of physical therapy,school of health sciences,shinshu university, Japan, department of physical therapy,school of health sciences,shinshu university, Japan, department of rehabilitation,matsumoto city hospital,matsumoto, Japan
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved