Use of a 24 gauge intravenous cannula for minimally invasive trabeculectomy
|
|
|
|
|
نویسنده
|
dada t. ,angmo d. ,temkar s. ,sharma r.
|
منبع
|
journal of ophthalmic and vision research - 2015 - دوره : 10 - شماره : 1 - صفحه:87 -89
|
چکیده
|
We describe an innovative technique for performing standardized low cost glaucoma filtration surgery using a polytetrafluoroethylene (ptfe) intravenous cannula. the trocar of a 24 gauge (24g) ptfe intravenous cannula was used to create a trabeculectomy ostium and its tube was inserted under a partial thickness scleral flap in 2 patients with advanced glaucomatous optic neuropathy,in whom intraocular pressure (iop) was not controlled on maximal tolerable hypotensive therapy. postoperatively,iop of the operated eyes at 3,6 and 9 months' follow-up ranged from 12 to 15 mmhg with a well formed anterior chamber and a diffuse bleb.
|
کلیدواژه
|
Cost Effective; ExPress Shunt; Glaucoma Drainage Devices; Intravenous Cannula; Polytetrafluoroethylene; Toxicity; Trabeculectomy
|
آدرس
|
glaucoma research facility and cinical services,dr. rajendra prasad centre for ophthalmic sciences,all india institute of medical sciences, India, glaucoma research facility and cinical services,dr. rajendra prasad centre for ophthalmic sciences,all india institute of medical sciences, India, glaucoma research facility and cinical services,dr. rajendra prasad centre for ophthalmic sciences,all india institute of medical sciences, India, glaucoma research facility and cinical services,dr. rajendra prasad centre for ophthalmic sciences,all india institute of medical sciences, India
|
|
|
|
|
|
|
|
|
|
|
|
|
|