   Manual Segmentation of 12 Layers of the Retina and Choroid through SD-OCT in Intermediate AMD: Repeatability and Reproducibility  
   
نویسنده camacho pedro ,dutra-medeiros marco ,salgueiro luís ,sadio sílvia ,rosa paulo c.
منبع journal of ophthalmic and vision research - 2021 - دوره : 16 - شماره : 3 - صفحه:384 -392
چکیده    Purpose: to evaluate the repeatability and reproducibility of the segmentation of 12 layers of the retina and the choroid, performed manually by sd-oct, along the horizontal meridian at three different temporal moments, and to evaluate its concordance with the same measurements performed by two other operators in intermediate amd. methods: a cross-sectional study of 40 eyes from 40 subjects with intermediate amd was conducted. the segmentation was performed manually, using sd-oct. the 169 measurements per eye were repeated at three time points to study the intra-operator variability. the same process was repeated a single time by two different trained operators for the inter-operator variability. results: forty participants (28 women and 12 men) were enrolled in this study, with an average age of 76.4 ± 8.2 (range, 55–92 years). overall, the maximum values of the various structures were found in the 3 mm of the macula. intra-operator variability: the highest icc values turned out to be discovered in thicker locations. inter-operator variability: except correlation values of 0.826 (0.727; 0.898) obtained in the opl (t2.5) and 0.634 (0.469; 0.771) obtained in the ipl (n2), all other correlation values were >0.92, in most cases approaching higher values like 0.98. conclusion: the measurements of several layers of the retina and the choroid achieved at 13 locations presented a good repeatability and reproducibility. manual quantification is still an alternative for the weaknesses of automatic segmentation. locations of greatest concordance should be those used for the clinical control and monitoring.
کلیدواژه Data Accuracy; Diagnostic Imaging; Macular Degeneration
آدرس ophtalmology institute dr. gama pinto, Portugal, instituto politécnico de lisboa, h&trc – health & technology research center, escola superior de tecnologia da saúde, Portugal. ophtalmology institute dr. gama pinto, Portugal. nova medical school, Portugal, central lisbon hospital center, Portugal. retina institute of lisbon, Portugal. nova medical school, Portugal, ophtalmology institute dr. gama pinto, Portugal, ophtalmology institute dr. gama pinto, Portugal. retina institute of lisbon, Portugal, ophtalmology institute dr. gama pinto, Portugal. retina institute of lisbon, Portugal
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved