>
Fa   |   Ar   |   En
   mean posterior corneal power and astigmatism innormal versus keratoconic eyes  
   
نویسنده feizi sepehr ,delfazayebaher siamak ,javadi mohammad ali ,karimian farid ,ownagh vahid ,sadeghpour fatemeh
منبع journal of ophthalmic and vision research - 2018 - دوره : 13 - شماره : 2 - صفحه:93 -100
چکیده    Purpose: to compare mean posterior corneal power and astigmatism in normal versus keratoconus affected eyes and determine the optimal cut-off points to maximize sensitivity and specificity in discriminating keratoconus from normal corneas. methods: a total of 204 normal eyes and 142 keratoconus affected eyes were enrolled in this prospective comparative study. mean posterior corneal power and astigmatism were measured using a dual scheimpflug camera. correlation coefficients were calculated to assess the relationship between the magnitudes of keratometric and posterior corneal astigmatism in the study groups. receiver operating characteristic curves were used to compare the sensitivity and specificity of the measured parameters and to identify the optimal cut-off points for discriminating keratoconus from normal corneas. results: the mean posterior corneal power was −6.29 ± 0.20 d in the normal group and −7.77 ± 0.87 d in the keratoconus group (p < 0.001). the mean magnitudes of the posterior corneal astigmatisms were −0.32 ± 0.15 d and −0.94 ± 0.39 d in the normal and keratoconus groups, respectively (p < 0.001). significant correlations were found between the magnitudes of keratometric and posterior corneal astigmatism in the normal (r=−0.76, p < 0.001) and keratoconus (r=−0.72, p < 0.001) groups. the mean posterior corneal power and astigmatism were highly reliable characteristics that distinguished keratoconus from normal corneas (area under the curve, 0.99 and 0.95, respectively). the optimal cut-off points of mean posterior corneal power and astigmatism were −6.70 d and −0.54 d, respectively. conclusion: mean posterior corneal power and astigmatism measured using a galilei analyzer camera might have potential in diagnosing keratoconus. the cut-off points provided can be used for keratoconus screening.
کلیدواژه keratoconus ,posterior corneal astigmatism ,posterior corneal power
آدرس shahid beheshti university of medical sciences, ocular tissue engineering research center, iran, shahid beheshti university of medical sciences, ophthalmic research center, iran, shahid beheshti university of medical sciences, ophthalmic research center, iran, shahid beheshti university of medical sciences, ophthalmic research center, iran, shahid beheshti university of medical sciences, ophthalmic research center, iran, shahid beheshti university of medical sciences, ophthalmic research center, iran
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved