Mersilene Mesh Vs Autogenous Fascia Lata for Upper Lid Sling Procedure
|
|
|
|
|
نویسنده
|
Salour Hossein ,Ale-Taha Maryam ,Bagheri Abbas
|
منبع
|
journal of ophthalmic and vision research - 2007 - دوره : 2 - شماره : 2 - صفحه:135 -140
|
چکیده
|
Purpose: to compare mersilene mesh and autogenous fascia lata for upper lid slingprocedure in the management of ptosis with poor levator function.methods: this randomized clinical trial included 9 patients with unilateral and 11patients with bilateral congenital ptosis and poor levator function. all subjects underwentupper lid sling procedure with a random choice of two different materials: mersilenemesh in 16 eyelids and autogenous fascia lata in 15 eyelids.results: overall, 31 eyelids underwent the upper lid sling procedure. there was nodifference between the two groups in terms of final functional (lid fissure height stability)and cosmetic (lid margin contour) results. dermatochalasis was more common inthe fascia lata group (10 eyes) compared to the mersilene mesh group (2 eyes). mersilenemesh extrusion occurred in two eyelids.conclusion: mersilene mesh has favorable long-term functional results and a low rate ofcomplications. this material may be considered as an alternative to autogenous fascialata for frontalis suspension surgery.
|
|
|
آدرس
|
shahid beheshti university of medical sciences, ایران, shahid beheshti university of medical sciences, ایران, shahid beheshti university of medical sciences, ایران
|
پست الکترونیکی
|
hosalour@hotmail.com
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|