protect electro pumps bearings from electric current flow (case study: recycling electro pump of dissolved air floatation in desalination plant)
|
|
|
|
|
|
|
|
نویسنده
|
asadi hamed ,beyrami masoud ,noroozi hamoon
|
|
منبع
|
هجدهمين كنفرانس ملي تخصصي پايش وضعيت و عيب يابي - 1403 - دوره : 18 - هجدهمین کنفرانس ملی تخصصی پایش وضعیت و عیب یابی - کد همایش: 03240-99558 - صفحه:0 -0
|
|
چکیده
|
Cause of using variable frequency drives induce capacitively coupled shaft voltages in the electric motors, motors with variable frequency drives can lead to complex shaft voltages and bearing currents. within an electric motor, many parts have electrical failure problems, and in the meantime, bearings are the most sensitive and vulnerable components, in this article we explain this problem had occurred in recycling electro pump of dissolved air floatation in desalination plant.
|
|
کلیدواژه
|
variable frequency drives ,edm ,bearing ,fluting
|
|
آدرس
|
, iran, , iran, , iran
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|