>
Fa   |   Ar   |   En
   calculation of dose perturbation in radiotherapy of head and neck tumors due to the presence of dental implants: a monte carlo study  
   
نویسنده hashemizadeh morteza ,shams nasim ,zabihzadeh mansour ,jamali masoud ,sedaghat zeinab ,azadbakht omid
منبع frontiers in biomedical technologies - 2024 - دوره : 11 - شماره : 4 - صفحه:651 -661
چکیده    Purpose: the presence of a dental implant across the irradiation beam has the potential to perturb the dose distribution. in this study, the effect of different commercial dental implants on dose distribution was investigated in electron beam therapy.materials and methods: the varian 2100 c/d linear accelerator (linac) head was modeled precisely with proper components for electron mode (6 and 9 mev) by mcnpx 2.6.1 and was benchmarked according to the international atomic energy agency (iaea) protocol, trs -398. dose distribution was calculated for six different implant materials, including titanium, titanium alloy, zirconia (y-tzp), zirconium oxide, alumina, and polyetheretherketone (peek), and for four different scenarios.results: the highest and lowest increasing doses occurred for y-tzp (114.44% and 108.69% for 6 and 9 mev, respectively) and peek (104.85% and 98.84% for 6 and 9 mev, respectively) directly in front of the implant, respectively. by removing an implant from the jaw, an increasing dose was not seen, but an increasing dose occurred behind its depths in the bone region (31.81 %).conclusion: the amount of dose perturbation due to the dental implant's presence depends on the beam energy, mass density, and atomic numbers of implants. maximum and minimum increased doses were estimated for y-tzp and peek implants, respectively. considering the correction factors due to the presence of high density and atomic number dental implants are essential to estimate the accurate dose delivery in radiotherapy with electron beams.
کلیدواژه dental implant ,dose distribution ,electron therapy ,monte carlo calculation ,radiotherapy ,head and neck tumors
آدرس ahvaz jundishapur university of medical sciences, school of medicine, department of medical physics, iran, ahvaz jondishapour university of medical sciences, school of dentistry, department of oral and maxillofacial radiology, iran, ahvaz jundishapur university of medical sciences, school of medicine, department of medical physics, iran, technical manager in sarerm hospital, iran, ahvaz jundishapur university of medical sciences, school of medicine, department of medical physics, iran, behbahan faculty of medical sciences, department of radiology technology, iran
پست الکترونیکی omidazadbakht68@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved