Fa   |   Ar   |   En
   characterization of the radiation contamination in an 18mv linac treatment room made of some nanoparticles mixture  
   
نویسنده ghanavati sara ,makiabadi nahid ,keshavarz sajad ,ghiasi hosein
منبع frontiers in biomedical technologies - 2023 - دوره : 10 - شماره : 4 - صفحه:449 -458
چکیده    The purpose of this study was to evaluate the risk of gonad cancer induction in adults with pelvic cancer (bladder, rectum, endometriosis) after radiation therapy. materials and methods: in two fractions of radiotherapy, thermo luminescence dosimeters (tlds) measured the peripheral dose to the testis and ovary. with 3d planning, all patients received a 45 gy total dose in four fields in the prone position. researchers investigated the doses produced by linear accelerators operating at 18 mev. results: the mean excess relative risk (err) was measured based on the beir iiv models. right pelvic radiotherapy of men was 0.795 ± 0.168 and 0.675 ± 0.134, and for women was 1.015 ± 0.561 and 0.884 ± 0.468 after 5 and 10 years of treatment, respectively. left pelvic radiotherapy was 0.855 ± 0.172, 0.725 ± 0.138 for men and 0.880 ± 0.464, 0.722 ± 0.342 for women respectively (95% confidence interval). these values for women were higher (p < 0.05). conclusion: estimating the second cancer risk of untargeted organs is crucial in radiotherapy. the out-of-field doses can be minimized by using a linear accelerator with a single energy mode and proper shields.
کلیدواژه monte carlo ,neutron ,n-xcom ,dose equivalent
آدرس university of science and research branch tehran, department of medical radiation engineering, iran, university of science and research branch tehran, department of medical radiation engineering, iran, university of science and research branch tehran, department of medical radiation engineering, iran, tabriz university of medical sciences, iran
پست الکترونیکی hoseinghiasi62@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved