   critical organ dose estimation from tc-99m-mibi in nuclear medicine cardiology based on distribution data in rats  
   
نویسنده fallahmohammadi gholamreza ,khorrami alireza ,abbaszadeh fariba ,mahdavi mohammad
منبع frontiers in biomedical technologies - 2023 - دوره : 10 - شماره : 1 - صفحه:102 -108
چکیده    Purpose: calculating the organs' radiation dosage in cardiac nuclear medicine procedures is essential in order to identify critical organs, radiation risk assessment and optimization dose value in the injection of radiopharmaceutical drugs. in this study, the biological distribution of 99mtc-2-methoxyisobutylisonitrile) 99mtc-mibi as the most common radiopharmaceutical in a cardiac study in human organs based on animal samples was investigated.materials and methods: after 99mtc-mibi preparation, radiopharmaceutical was injected into 15 rats. after sacrificing rats, the uptake of radiopharmaceuticals in critical organs at 15, 30, and 45 minutes was measured using an high purity germanium (hpge) detector and the percentage of injected dose per gram of organs was calculated. the cumulative activity was calculated from the radiopharmaceutical transformation diagram with time. the absorption of a radioactive complex in human organs based on animal data was calculated by applying a correction factor. the organs dose was calculated using s factor and the effective dose was calculated using tissue weighting factors.results: the mean effective dose per unit of activity was 0.0062 msv/mbq. the mean effective dose of 27.5 mci radiopharmaceutical injection was 6.3 msv. in this study, the absorbed dose in blood, heart, lung, thyroid, liver, spleen, stomach wall, muscle, and bone was calculated as 0.28, 2.92, 1.85, 24.82, 11.13, 7.03, 20.95, 1.11, 4.97, and 22.22 mgy, respectively.conclusion: the effective dose of human organs based on the animal model in the study of cardiac nuclear medicine was evaluated by injection of 99mtc-mibi radiopharmaceutical. the kidneys, salivary glands, thyroid, and spleen were the most critical organs that should be considered in dose optimization studies. the effective dose limit was 28% lower than the values reported in international references.
کلیدواژه absorption dose ,biodistribution ,internal dosimetry ,nuclear medicine ,99tc-methoxyisobutylisonitrile
آدرس mazandaran university of medical sciences, faculty of allied medicine, department of radiology, iran, mazandaran university of medical sciences, faculty of allied medicine, department of radiology, iran, university of mazandaran, department of physics, iran, mazandaran university of medical sciences, faculty of allied medicine, department of radiology, iran
پست الکترونیکی m.mahdavi@umz.ac.ir
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved