>
Fa   |   Ar   |   En
   surface and the build-up dose distribution due to applying thermoplastic masks in external radiotherapy  
   
نویسنده pourfallah tayyeb ,pirzadeh masoud ,seifi makrani danial ,mihandoust ehsan ,davodian saeed
منبع frontiers in biomedical technologies - 2020 - دوره : 7 - شماره : 4 - صفحه:217 -225
چکیده    Background: thermoplastic immobilization devices are used to position the patient on the table in order to correctly reposition the patient during treatment courses.objective: the purpose of this work is investigating the degradation of surface dose and the dose distribution in the build-up region for photon beams associated with immobilization devices using gafchromic films.materials and methods: after heating, these masks are stretched and fitted over the considered location of body before treatment simulation for insuring the reproducibility of patient position during treatment fractions. in this research, dosimetry was carried out using gafchromic ebt3 film and three kinds of thermoplastic masks (orfit with thickness 2.2mm, holes diameter 2.5mm, orfit with thickness 2mm, holes diameter 1mm, and klarity mask, thickness 2mm, holes diameter 3mm). measurements were made with and without the mask materials on the surface of the perspex phantom for 6 and 15 mv x-ray beams of a linac machine.results: the results showed that surface dose increases 2.1 to 6.7 times and 2 to 3.9 times than the surface dose in the open field for 15 mv and 6 mv photons, respectively. according to the obtained results from the analyses of variances (anova) test , it is defined that there is a significant difference in surface dose among three kind of thermoplastic masks (χ2=49.78 and df=3 and p<0.0001). the surface dose in klarity has a significant difference in comparison of other masks according to posthoc exams and there is no significant difference among two other masks (p>0.05).conclusion: according to the results, klarity mask is more acceptable immobilization device when compared with other masks in the test.
کلیدواژه thermoplastic mask ,linear accelerator ,surface dose
آدرس mazandaran university of medical sciences, faculty of medicine, department of biochemistry, biophysics & genetics, department of medical physics, iran, mazandaran university of medical sciences, faculty of medicine, iran, tehran university of medical sciences, school of medicine, department of medical physics and biomedical engineering, iran, mazandaran university of medical sciences, radiotherapy center, imam khomeini hospital, iran, mazandaran university of medical sciences, radiotherapy center, imam khomeini hospital, iran
پست الکترونیکی s.davoudian@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved