Fa   |   Ar   |   En
   llclc load resonant converter for application as a constant current source without any feedback loop  
   
DOR 20.1001.2.9819038881.1399.2.1.122.0
نویسنده khoshsaadat alireza ,abedini mohammad
منبع همايش ملي پژوهش هاي نوين در مهندسي و علوم كاربردي - 1399 - دوره : 2 - دومین همایش ملی پژوهش های نوین در مهندسی و علوم کاربردی - کد همایش: 98190-38881 - صفحه:1 -9
چکیده    In this paper a llclc passive resonant tank (prt) is designed using a method based on minimization of kva/kw characteristic for application in constant current load resonant converter (lrc). designed circuit is a converter that has output current with high robustness against load variation without using a feedback loop. also, minimum reactive power and zvs operation on the inverter’s switches in a wide range of load variation are achieved. finally, a 70w lrc is presented as an experimental prototype of the designed converter.
کلیدواژه load resonant converter ,constant output current ,passive resonant tank (prt)
آدرس ayatollah boroujerdi university (abru), iran, ayatollah boroujerdi university (abru), iran
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved