comparative experimental study on seismic retrofit of existing gas risers
|
|
|
DOR
|
20.1001.2.9819010854.1398.8.1.130.7
|
نویسنده
|
safi mohammad ,hassani nemet ,beheshti seyed saeed ,mohammad saleh hosein ,samadian masood ,zangeneh kaveh
|
منبع
|
كنفرانس بين المللي زلزله شناسي و مهندسي زلزله - 1398 - دوره : 8 - هشتمین کنفرانس زلزله شناسی و مهندسی زلزله - کد همایش: 98190-10854 - صفحه:1 -2
|
چکیده
|
Distribution system for this lifeline consists of several critical components including pipelines, valves, stations, pumps, distribution lines and finally the risers. riser as the last element at costumer location has the most uncertainty in seismic vulnerability because its performance under earthquake load highly depends on characteristics of the customer buildingand its seismic behavior which cannot easily have considered in seismic design of the riser. this paper presents the results of an extensive experimental and numerical investigation on seismic behavior and retrofit of riser system. several tests have been conducted on full scale risers with real conditions to assess the performance of existing risers in different loadscenarios. after finding the weak points and failure modes, several retrofit countermeasures have been implemented to find the best solutions for upgrading the seismic performance of the system considering the assessment and modification on all minor and major components of the connections. the results have been developed numerically to obtain the detailsof stress and deformation distribution using calibrated models. finally, the best solutions as innovative countermeasures have been presented. gas riser system has been used in many large cities including the capital and several other seismic prone areas. the damage histories show that the existing system has a high vulnerability and requires appropriatecountermeasures (gross, 1985). in the capital city of tehran itself there are more than one million risers with different sizes and more than ten million residents. similar condition exists in other large cities in iran. this fact raises the importance of finding an appropriate retrofit solution for the issue.
|
کلیدواژه
|
gas riser ,seismic performance ,experimental evaluation ,retrofit design
|
آدرس
|
shahid beheshti university, iran, shahid beheshti university, iran, shahid beheshti university, iran, tehran province gas company, iran, tehran province gas company, iran, tehran province gas company, iran
|
پست الکترونیکی
|
ksveh.zanganeh@gmail.com
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|